1.5 mva transformer manufacturers in india

buy from 1.5 mva dry type transformer, 1.5 mva oil filled transformer suppliers in africa, view 1500 kva transformer price in india

There are various types of 1.5 mva transformer specification used in the electrical power system. This 1.5 mva transformer dimension is  meant for different purposes, like generation, distribution and transmission as well as the utilization of electrical power. There are several different types of transformers.

1.5 mva transformer manufacturers in india

 

 

1.5 mva transformer manufacturers in india
1.5 mva transformer manufacturers in india
1500 kva transformer
1500 kva transformer
1.5 mva dry type transformer
1.5 mva dry type transformer

 

Prestige Quality 1500 kva transformer, 1.5 mva transformer Exporter in india, view 1.5 mva transformer price.

For instance  Step up and Step down Transformer, Single phase and Three phase transformer,  Power Transformer, 1500 kva dry type transformer , Distribution Transformer, Instrument transformer comprising current and Potential Transformer as well as Auto transformer, etc. We are reputed 1.5 mva transformer manufacturers in India. Click here to know more about the 1500 kva transformer price in India

A Transformer, such as the 1.5 mva dry type transformer is a static electrical machine which can transfers AC or alternating current electrical power from one circuit to the other circuit at the constant frequency. But the voltage level in a 1.5 mva oil filled transformer could be altered, which means that means voltage on the 1.5 mva transformer can be increased or decreased according to the requirement by the buyer. Click there to learn more about the 1.5 mva transformer price.

Volt ampere is a unit used to describe or is a unit which can be used to measure e.g. 1500 kva transformer the electrical load in engineering. Hence, it takes 1,000 kilo-volt amperes or KVA  to get one mega-volt ampere or MVA. Which would mean that the number of kVA has to be divided by 1,000 to convert to MVA. For example, if you have 1500 kva dry type transformer, divide 1500 by 1,000 to get 1.5 mva transformer weight.

A pad mount or 1500 kva pad mount transformer dimensions is a ground mounted electric power distribution type of transformer. This pad mounted transformer 1500 kva is then in a locked steel cabinet to be mounted on a concrete pad. Select the link here for the 1500 kva pad mounted transformer price.

 

what is 1.5 mva transformer ?

MVA stands for Mega Volt Amp or Volts X Amp /1000,000. In the event that your total load necessity is 1000 volts and 5000 amps (1000 x 5000 = 5000,000 VA) it can be expressed as 5MVA. We right now manufacture 5kVA to 1.5MVA Transformers (3 Phase Transformers). Auto transformers have the advantage of being littler and cheaper than twofold wound transformers. We will make essentially any estimate of single or 3 phase transformer, dependant on voltage.

Our Three and Single phase transformers can be planned particularly to meet all of your prerequisites, no matter how unusual. We manufacture transformers for a wide extend of industries,if you’ve got particular prerequisites for your 3 phase transformers at that point please request a cite along with your points of interest or get in touch via phone, we’re here to assist!

1.5 MVA = 1500kVA

 

1.5 mva transformer specification

Rating 1.5MVA, 3PH, 415/6.6/11KV
Frequency 50 HZ
LT Nominal Voltage 415V, AC
LT Breaker 3200A, 3P, 415V MDO
HT Nominal Voltage 6.6/11KV, AC
CT Ratio 100/5A
PT Ratio 11/110V
Capacity of Oil 250 LTR
Type of Oil TC OIL
Vector Group Y-Y
Empty Weight 8000KG
Full Weight 7000KG
Provisions Can For Step Up and Step Down Application for Step Down Application Load Should be Balanced on 3PH
1 mva transformer manufacturers export to Bangladesh, Uganda, Tanzania, Africa, Rwanda, India, Malaysia Nigeria, Nepal, Kenya, Malawi
Other Ratings 10, 16, 25, 50, 63, 100, 160, 200, 315, 500, 630, 750 kVA
all above transformer are 11kV , 22kV, 33kV line
Efficiency 3, 4, 5 Star or Level II, Level III

 

1.5 mva transformer price

For Final 1500 kva pad mounted transformer price Please Mail Us on info@rajasthanpower.in

 

1.5 mva transformer manufacturers in india

1.5 mva dry type transformer
1.5 mva dry type transformer
1.5 mva oil filled transformer
1.5 mva oil filled transformer
1.5 mva transformer
1.5 mva transformer
1500 kva dry type transformer
1500 kva dry type transformer
1500 kva pad mounted transformer
1500 kva pad mounted transformer
1500 kva oil filled transformer
1500 kva oil filled transformer
1.5 mva transformer
1.5 mva transformer
1500 kva transformer
1500 kva transformer

 

Request A Quote Today For 1500 kva dry type transformer, transformer 1500kva, Check 1500 kva pad mount transformer dimensions and 1500 kva transformer amps

 

1500 kva transformer to kw

The real power P in kilowatts (kW) is equal to the apparent power S in kilovolt-amps (kVA), times the power factor PF:

P(kW) =  S(kVA) × PF

 

transformer 1500 kva amps

Formulas Used In Calculation:

1-Phase KVA = Volts x Amps / 1000
1-Phase Amps = KVA / Volts x 1000
3-Phase KVA = Volts x Amps x 1.732 / 1000
3-Phase Amps = KVA / Volts / 1.732 x 1000

Generator KVA Rating to Amperage Conversion Chart
80% POWER FACTOR
kV•A kW 208V 220V 240V 380V 440V 480V 600V 2400V 3300V 4160V
6.3 5 17.5 16.5 15.2 9.6 8.3 7.6 6.1
9.4 7.5 26.1 24.7 22.6 14.3 12.3 11.3 9.1
12.5 10 34.7 33 30.1 19.2 16.6 15.1 12
18.7 15 52 49.5 45 28.8 24.9 22.5 18
25 20 69.5 66 60.2 38.4 33.2 30.1 24 6 4.4 3.5
31.3 25 87 82.5 75.5 48 41.5 37.8 30 7.5 5.5 4.4
37.5 30 104 99 90.3 57.6 49.8 45.2 36 9.1 6.6 5.2
50 40 139 132 120 77 66.5 60 48 12.1 8.8 7
62.5 50 173 165 152 96 83 76 61 15.1 10.9 8.7
75 60 208 198 181 115 99.5 91 72 18.1 13.1 10.5
93.8 75 261 247 226 143 123 113 90 22.6 16.4 13
100 80 278 264 240 154 133 120 96 24.1 17.6 13.9
125 100 347 330 301 192 166 150 120 30 21.8 17.5
156 125 433 413 375 240 208 188 150 38 27.3 22
187 150 520 495 450 288 249 225 180 45 33 26
219 175 608 577 527 335 289 264 211 53 38 31
250 200 694 660 601 384 332 301 241 60 44 35
312 250 866 825 751 480 415 376 300 75 55 43
375 300 1040 990 903 576 498 451 361 90 66 52
438 350 1220 1155 1053 672 581 527 422 105 77 61
500 400 1390 1320 1203 770 665 602 481 120 88 69
625 500 1735 1650 1504 960 830 752 602 150 109 87
750 600 2080 1980 1803 1150 996 902 721 180 131 104
875 700 2430 2310 2104 1344 1274 1052 842 210 153 121
1000 800 2780 2640 2405 1540 1330 1203 962 241 176 139
1125 900 3120 2970 2709 1730 1495 1354 1082 271 197 156
1250 1000 3470 3300 3009 1920 1660 1504 1202 301 218 174
1563 1250 4350 4130 3740 2400 2080 1885 1503 376 273 218
1875 1500 5205 4950 4520 2880 2490 2260 1805 452 327 261
2188 1750 5280 3350 2890 2640 2106 528 380 304
2500 2000 6020 3840 3320 3015 2405 602 436 348
2812 2250 6780 4320 3735 3400 2710 678 491 392
3125 2500 7520 4800 4160 3740 3005 752 546 435
3750 3000 9040 5760 4980 4525 3610 904 654 522
4375 3500 10550 6700 5780 5285 4220 1055 760 610
5000 4000 12040 7680 6640 6035 4810 1204 872 695

 

1.5 mva transformer rating

kVA stands for Kilovolt-Ampere and is the rating regularly utilized to rate a transformer. The size of a transformer is decided by the kVA of the load. In numerous circumstances the power required by the load is proportionate to the rating of the transformer communicated in either VA or kVA. For case a 1KW (1000 Watts) load would require a 1kVA transformer @ unity power factor.

KVA calculation
For three phase KVA= (V*I*1.732)/1000
For single phase KVA= (V*I)/1000

MVA calculation-
For three phase MVA= (V*I*1.732)/100,000
For single phase MVA= (V*I)/1000,000

 

Get All Type Test Report Here

5 MVA Lightning Impulse Test Report 5 MVA Short circuit Test Report 5 MVA Temperature Rise Test Report
3.15 MVA Lightning Impulse Test Report 3.15 MVA Short Circuit Test Report 3.15 MVA Temperature Rise Test Report
2000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report 1000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report 500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Paint Adhesion Test Report 500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report 315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report 315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Sound Power Test Report 315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report 160 KVA, Lightning Impulse Test Report
160 KVA, Short Circuit Test Report 160 KVA, Temperature Rise Test Report 100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Lightning Impulse Test Report
100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report 100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Short Circuit Test Report 100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Sound Power Test Report 100 KVA Aluminium Wound Distribution Transformer Temperature Rise Test Report
63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Sound Power Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report 10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report
10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report Single Phase 25 KVA ALuminium wound Distribution Transformer EEL-2 Single Phase 16 KVA ALuminium wound Distribution Transformer EEL-2
Single Phase 10 KVA ALuminium wound Distribution Transformer EEL-2 Single Phase 5 KVA Aluminium wound Distribution Transformer EEL-2 Single Phase 5 KVA Copper wound Distribution Transformer EEL-2

 

1.5 mva transformer dimension

Power Max Voltage Weight of Oil Active Section Weight Total Weight Leng. A Wid. B Heig. C D F ØG L M N S T
kVA kV kg kg kg mm mm mm mm mm mm mm mm mm mm mm
315 KVA 6,3-11 245 820 1295 1525 750 1740 1035 670 150 50 310 330  178 150
15 270 840 1315 1540 760 1750 1040 385 330
33 295 850 1330 1600 775 1805 1105 485 350
400 KVA 6,3-11 255 910 1360 1370 775 1595 1070 670 150 50 310 265  138 150
15 290 960 1460 1495 775 1710 1115 385 265
33 335 965 1525 1600 775 8155 1155 485 330
500 KVA 6,3-11 300 1100 160 1600 760 1700 1150 670 150 50 310 330  263 150
15 315 1145 1690 1625 775 1765 1165 385 330
33 380 1175 1800 1675 805 1920 1220 485 350
630 KVA 6,3-11 350 1280 1900 1680 790 1785 1185 670 150 50 310 330  263 150
15 340 1285 1895 1640 785 1780 1185 385 330
33 440 1405 2135 1700 810 1945 1255 485 350
800 KVA 6,3-11 480 1530 2335 1860 945 1835 1190 820 150 50 310 400  263 150
15 475 1585 2385 1845 925 1870 1225 385
33 560 1625 2515 1950 925 2000 1255 485
1000 KVA 6,3-11 540 1760 2690 1910 990 1900 1330 820 200 70 310 400 340 150
15 565 1840 2780 1915 965 1975 1330 385
33 650 1855 2900 1950 1015 2090 1360 485
1250 KVA 6,3-11 685 2070 3345 2050 1010 2025 1380 820 200 70 310 400 340 150
15 670 2080 3345 2015 995 2090 1400 385
33 760 2130 3495 2005 1005 2245 1455 485
1600 KVA 6,3-11 825 2415 4010 2100 1130 2110 1420 820 200 70 310 400  372 200
15 855 2545 4155 2020 1125 2110 1420 385
33 1000 2858 4405 2090 1185 2245 1455 485
2000 KVA 6,3-11 1025 2730 4785 2265 1250 2255 1525 1000 200 70 310 400 372 200
15 1080 2765 4895 2270 1260 2160 1430 385
33 1185 2745 4985 2270 1275 2465 1635 485
2500 KVA 6,3-11 1420 3645 6300 2395 1710 2365 1625 1000 200 70 310 400  450 330
15 1445 3630 6300 2395 1710 2380 1640 385
33 1485 3625 6345 2395 1410 2525 1690 485

 

1.5 mva transformer weight

Power Max Voltage Weight of Oil Active Section Weight Total Weight Leng. A Wid. B Heig. C D F ØG L M N S T
kVA kV kg kg kg mm mm mm mm mm mm mm mm mm mm mm
315 KVA 6,3-11 245 820 1295 1525 750 1740 1035 670 150 50 310 330  178 150
15 270 840 1315 1540 760 1750 1040 385 330
33 295 850 1330 1600 775 1805 1105 485 350
400 KVA 6,3-11 255 910 1360 1370 775 1595 1070 670 150 50 310 265  138 150
15 290 960 1460 1495 775 1710 1115 385 265
33 335 965 1525 1600 775 8155 1155 485 330
500 KVA 6,3-11 300 1100 160 1600 760 1700 1150 670 150 50 310 330  263 150
15 315 1145 1690 1625 775 1765 1165 385 330
33 380 1175 1800 1675 805 1920 1220 485 350
630 KVA 6,3-11 350 1280 1900 1680 790 1785 1185 670 150 50 310 330  263 150
15 340 1285 1895 1640 785 1780 1185 385 330
33 440 1405 2135 1700 810 1945 1255 485 350
800 KVA 6,3-11 480 1530 2335 1860 945 1835 1190 820 150 50 310 400  263 150
15 475 1585 2385 1845 925 1870 1225 385
33 560 1625 2515 1950 925 2000 1255 485
1000 KVA 6,3-11 540 1760 2690 1910 990 1900 1330 820 200 70 310 400 340 150
15 565 1840 2780 1915 965 1975 1330 385
33 650 1855 2900 1950 1015 2090 1360 485
1250 KVA 6,3-11 685 2070 3345 2050 1010 2025 1380 820 200 70 310 400 340 150
15 670 2080 3345 2015 995 2090 1400 385
33 760 2130 3495 2005 1005 2245 1455 485
1600 KVA 6,3-11 825 2415 4010 2100 1130 2110 1420 820 200 70 310 400  372 200
15 855 2545 4155 2020 1125 2110 1420 385
33 1000 2858 4405 2090 1185 2245 1455 485
2000 KVA 6,3-11 1025 2730 4785 2265 1250 2255 1525 1000 200 70 310 400 372 200
15 1080 2765 4895 2270 1260 2160 1430 385
33 1185 2745 4985 2270 1275 2465 1635 485
2500 KVA 6,3-11 1420 3645 6300 2395 1710 2365 1625 1000 200 70 310 400  450 330
15 1445 3630 6300 2395 1710 2380 1640 385
33 1485 3625 6345 2395 1410 2525 1690 485

 

types of industrial transformer available

 

1500 kva transformer full load current

How to use the full load chart to find kVA

A) Determine the secondary voltage of your transformer.
B) Sum up the total amperes required by the load.
C) From the full load current table below, select a transformer under the corresponding secondary voltage, with a standard kVA capacity and amperage equal to or higher than the sum required by the load.

 

Full Load Current Table (1 Phase Transformer)

kVA Current in Amperes
120V 240V 416V 480V 600V 2400V 4160V
0.25 2.08 1.04 0.6 0.52 0.41
0.5 4.16 2.08 1.2 1.04 0.83
0.75 6.25 3.13 1.8 1.56 1.25
1 8.33 4.17 2.4 2.08 1.67
1.5 12.5 6.25 3.6 3.13 2.5
2 16.7 8.33 4.81 4.17 3.33
3 25 12.5 7.21 6.25 5 1.25 0.72
5 41.6 20.8 12 10.4 8.33 2.08 1.2
7.5 62.5 31.2 18 15.6 12.5 3.12 1.8
10 83.3 41.6 24 20.8 16.6 4.16 2.4
15 125 62.5 36 31.2 25 6.25 3.6
25 208 104 60 52 41.6 10.4 6
37.5 312 156 90.1 78.1 62.5 15.6 9.01
50 416 208 120 104 83.3 20.8 12
75 625 312 180 156 125 31.2 18
100 833 416 240 208 166 41.6 24
150 1250 625 360 312 250 62.5 36
167 1391 695 401 347 278 69.5 40.1
250 2083 1041 600 520 416 104 60
333 2775 1387 800 693 555 138 80

 

 

Single Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

 

Horsepower Full Load Current (Amps) Minimum Transformer KVA
110-120V 208V 220-240V*
0.5 9.8 5.4 4.9 1.5
0.75 13.8 7.6 6.9 2
1 16 8.8 8 3
1.5 20 11 10 3
2 24 13.2 12 5
3 34 18.7 17 5
5 56 30.8 28 7.5
7.5 80 44 40 15
10 100 55 50 15
15 135 74.8 68 25
20 88 25
25 110 37.5
30 136 37.5
40 176 50
50 216 75

kVA ratings include 10% overcapacity for frequent motor starts.

*For 200 volt motors, increase 220-240V ratings by 15%.

 

Full Load Current Table – 3 Phase Transformer?

kVA Current in Amperes
208V 240V 380V 416V 480V 600V 2400V 4160V
2 KVA 5.55 4.81 3.03 2.77 2.4 1.92 0.48 0.27
3 KVA 8.32 7.21 4.55 4.16 3.6 2.88 0.72 0.41
6 KVA 16.6 14.4 9.11 8.32 7.21 5.77 1.44 0.83
9 KVA 24.9 21.6 13.6 12.4 10.8 8.66 2.16 1.24
15 KVA 41.6 36 22.7 20.8 18 14.4 3.6 2.08
30 KVA 83.2 72.1 45.5 41.6 36 28.8 7.21 4.16
45 KVA 124 108 68.3 62.4 54.1 43.3 10.8 6.24
75 KVA 208 180 113 104 90.2 72.1 18 10.4
112.5 KVA 312 270 170 156 135 108 27 15.6
150 KVA 416 360 227 208 180 144 36 20.8
225 KVA 624 541 341 312 270 216 54.1 31.2
300 KVA 832 721 455 416 360 288 72.1 41.6
450 KVA 1249 1082 683 624 541 433 108 62.4
500 KVA 1387 1202 759 693 601 481 120 69.3
600 KVA 1665 1443 911 832 721 577 144 83.2
750 KVA 2081 1804 1139 1040 902 721 180 104

 

 

Three Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

 

Horsepower Full Load Current (Amps) Minimum Transformer kVA
110-120V 208V 220-240V* 440-480V 550-600V
0.5 4 2.2 2 1 0.8 3
0.75 5.6 3.1 2.8 1.4 1.1 3
1 7.2 4 3.6 1.8 1.4 3
1.5 10.4 5.7 5.2 2.6 2.1 3
2 13.6 7.5 6.8 3.4 2.7 6
3 19.2 10.7 9.6 4.8 3.9 6
5 30.4 16.7 15.2 7.6 6.1 9
7.5 44 24 22 11 9 15
10 56 31 28 14 11 15
15 84 46 42 21 17 30
20 108 59 54 27 22 30
25 136 75 68 34 27 45
30 160 88 80 40 32 45
40 208 114 104 52 41 75
50 260 143 130 65 52 75
60 170 154 77 62 75
75 211 192 96 77 112.5
100 273 248 124 99 150

kVA ratings include 10% overcapacity for frequent motor starts.

* For 200 volt motors, increase 220-240V ratings by 15%.

 

1.5 mva transformer for sale

  • 1.5 mva transformer
  • 1500 kva transformer
  • transformer 1500 kva
  • 1500 kva dry type transformer
  • transformer 1500kva
  • 1500 kva pad mounted transformer
  • 1.5 mva oil filled transformer
  • 1500 kva oil filled transformer
  • 1.5 mva dry type transformer
  • 1500 kva transformer to kw
  • 1.5 mva pad mounted transformer

 

CPRI Aprroved transformer 1500 kva manufacturers, see 1500 kva dry type transformer weight and 1.5 mva transformer specification
ERDA Approved 1500 kva oil filled transformer suppliers, find here 1500 kva transformer full load current, 1500 kva transformer dimensions, 1.5 mva transformer weight