Rajasthan power

1.5 MVA distribution transformer manufacturers

Buy from 1.5 mva dry type transformer, 1.5 mva oil filled transformer suppliers in africa, view 1500 kva transformer price in india

1.5-mva-transformer-manufacturers-in-india

There are various types of 1.5 mva transformer specification used in the electrical power system. This 1.5 mva transformer dimension is meant for different purposes, like generation, distribution and transmission as well as the utilization of electrical power. There are several different types of transformers.

1.5 mva transformer manufacturers in india

1.5 mva transformer

1500 kva transformer

1500 kva transformer

1.5 mva dry type transformer

1.5 mva dry type transformer

Prestige Quality 1500 kva transformer, 1.5 mva transformer Exporter in india, view 1.5 mva transformer price.

For instance  Step up and Step down Transformer, Single phase and Three phase transformer,  Power Transformer, 1500 kva dry type transformer , Distribution Transformer, Instrument transformer comprising current and Potential Transformer as well as Auto transformer, etc. We are reputed 1.5 mva transformer manufacturers in India. Click here to know more about the 1500 kva transformer price in India

A Transformer, such as the 1.5 mva dry type transformer is a static electrical machine which can transfers AC or alternating current electrical power from one circuit to the other circuit at the constant frequency. But the voltage level in a 1.5 mva oil filled transformer could be altered, which means that means voltage on the 1.5 mva transformer can be increased or decreased according to the requirement by the buyer. Click there to learn more about the 1.5 mva transformer price.

Volt ampere is a unit used to describe or is a unit which can be used to measure e.g. 1500 kva transformer the electrical load in engineering. Hence, it takes 1,000 kilo-volt amperes or KVA  to get one mega-volt ampere or MVA. Which would mean that the number of kVA has to be divided by 1,000 to convert to MVA. For example, if you have 1500 kva dry type transformer, divide 1500 by 1,000 to get 1.5 mva transformer weight.

A pad mount or 1500 kva pad mount transformer dimensions is a ground mounted electric power distribution type of transformer. This pad mounted transformer 1500 kva is then in a locked steel cabinet to be mounted on a concrete pad. Select the link here for the 1500 kva pad mounted transformer price.

what is 1.5 mva transformer ?

MVA stands for Mega Volt Amp or Volts X Amp /1000,000. In the event that your total load necessity is 1000 volts and 5000 amps (1000 x 5000 = 5000,000 VA) it can be expressed as 5MVA. We right now manufacture 5kVA to 1.5MVA Transformers (3 Phase Transformers). Auto transformers have the advantage of being littler and cheaper than twofold wound transformers. We will make essentially any estimate of single or 3 phase transformer, dependant on voltage.

Our Three and Single phase transformers can be planned particularly to meet all of your prerequisites, no matter how unusual. We manufacture transformers for a wide extend of industries,if you’ve got particular prerequisites for your 3 phase transformers at that point please request a cite along with your points of interest or get in touch via phone, we’re here to assist!

1.5 MVA = 1500kVA

1.5 mva transformer specification

Rating1.5MVA, 3PH, 415/6.6/11KV
Frequency50 HZ
LT Nominal Voltage415V, AC
LT Breaker3200A, 3P, 415V MDO
HT Nominal Voltage6.6/11KV, AC
CT Ratio100/5A
PT Ratio11/110V
Capacity of Oil250 LTR
Type of OilTC OIL
Vector GroupY-Y
Empty Weight8000KG
Full Weight7000KG
ProvisionsCan For Step Up and Step Down Application for Step Down Application Load Should be Balanced on 3PH
1 mva transformer manufacturers export toBangladesh, Uganda, Tanzania, Africa, Rwanda, India, Malaysia Nigeria, Nepal, Kenya, Malawi
Other Ratings10, 16, 25, 50, 63, 100, 160, 200, 315, 500, 630, 750 kVA
all above transformer are11kV , 22kV, 33kV line
Efficiency3, 4, 5 Star or Level II, Level III

1.5 mva transformer price

For Final 1500 kva pad mounted transformer price Please Mail Us on info@rajasthanpower.in

1.5 mva transformer manufacturers in india

Request A Quote Today For 1500 kva dry type transformer, transformer 1500kva, Check 1500 kva pad mount transformer dimensions and 1500 kva transformer amps

1500 kva transformer to kw

The real power P in kilowatts (kW) is equal to the apparent power S in kilovolt-amps (kVA), times the power factor PF:

P(kW) =  S(kVA) × PF

transformer 1500 kva amps

Formulas Used In Calculation:

1-Phase KVA = Volts x Amps / 1000
1-Phase Amps = KVA / Volts x 1000
3-Phase KVA = Volts x Amps x 1.732 / 1000
3-Phase Amps = KVA / Volts / 1.732 x 1000

Generator KVA Rating to Amperage Conversion Chart
80% POWER FACTOR
kV•AkW208V220V240V380V440V480V600V2400V3300V4160V
6.3517.516.515.29.68.37.66.1   
9.47.526.124.722.614.312.311.39.1   
12.51034.73330.119.216.615.112   
18.7155249.54528.824.922.518   
252069.56660.238.433.230.12464.43.5
31.3258782.575.54841.537.8307.55.54.4
37.5301049990.357.649.845.2369.16.65.2
50401391321207766.5604812.18.87
62.5501731651529683766115.110.98.7
756020819818111599.5917218.113.110.5
93.8752612472261431231139022.616.413
100802782642401541331209624.117.613.9
1251003473303011921661501203021.817.5
1561254334133752402081881503827.322
187150520495450288249225180453326
219175608577527335289264211533831
250200694660601384332301241604435
312250866825751480415376300755543
3753001040990903576498451361906652
4383501220115510536725815274221057761
5004001390132012037706656024811208869
62550017351650150496083075260215010987
7506002080198018031150996902721180131104
875700243023102104134412741052842210153121
1000800278026402405154013301203962241176139
11259003120297027091730149513541082271197156
125010003470330030091920166015041202301218174
156312504350413037402400208018851503376273218
187515005205495045202880249022601805452327261
21881750  52803350289026402106528380304
25002000  60203840332030152405602436348
28122250  67804320373534002710678491392
31252500  75204800416037403005752546435
37503000  90405760498045253610904654522
43753500  1055067005780528542201055760610
50004000  1204076806640603548101204872695

1.5 mva transformer rating

kVA stands for Kilovolt-Ampere and is the rating regularly utilized to rate a transformer. The size of a transformer is decided by the kVA of the load. In numerous circumstances the power required by the load is proportionate to the rating of the transformer communicated in either VA or kVA. For case a 1KW (1000 Watts) load would require a 1kVA transformer @ unity power factor.

KVA calculation
For three phase KVA= (V*I*1.732)/1000
For single phase KVA= (V*I)/1000

MVA calculation-
For three phase MVA= (V*I*1.732)/100,000
For single phase MVA= (V*I)/1000,000

Get All Type Test Report Here

5 MVA Lightning Impulse Test Report5 MVA Short circuit Test Report5 MVA Temperature Rise Test Report
3.15 MVA Lightning Impulse Test Report3.15 MVA Short Circuit Test Report3.15 MVA Temperature Rise Test Report
2000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report1000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Paint Adhesion Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Sound Power Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report160 KVA, Lightning Impulse Test Report
160 KVA, Short Circuit Test Report160 KVA, Temperature Rise Test Report100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Lightning Impulse Test Report
100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Short Circuit Test Report100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Sound Power Test Report100 KVA Aluminium Wound Distribution Transformer Temperature Rise Test Report
63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Sound Power Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report
10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test ReportSingle Phase 25 KVA ALuminium wound Distribution Transformer EEL-2Single Phase 16 KVA ALuminium wound Distribution Transformer EEL-2
Single Phase 10 KVA ALuminium wound Distribution Transformer EEL-2Single Phase 5 KVA Aluminium wound Distribution Transformer EEL-2Single Phase 5 KVA Copper wound Distribution Transformer EEL-2

types of industrial transformer available

1.5 mva transformer dimension

PowerMax VoltageWeight of OilActive Section WeightTotal WeightLeng. AWid. BHeig. CDFØGLMNST
kVAkVkgkgkgmmmmmmmmmmmmmmmmmmmmmm
315 KVA6,3-11245820129515257501740103567015050310330 178150
152708401315154076017501040385330
332958501330160077518051105485350
400 KVA6,3-11255910136013707751595107067015050310265 138150
152909601460149577517101115385265
333359651525160077581551155485330
500 KVA6,3-11300110016016007601700115067015050310330 263150
1531511451690162577517651165385330
3338011751800167580519201220485350
630 KVA6,3-113501280190016807901785118567015050310330 263150
1534012851895164078517801185385330
3344014052135170081019451255485350
800 KVA6,3-114801530233518609451835119082015050310400 263150
1547515852385184592518701225385
3356016252515195092520001255485
1000 KVA6,3-115401760269019109901900133082020070310400340150
1556518402780191596519751330385
33650185529001950101520901360485
1250 KVA6,3-1168520703345205010102025138082020070310400340150
1567020803345201599520901400385
33760213034952005100522451455485
1600 KVA6,3-1182524154010210011302110142082020070310400 372200
15855254541552020112521101420385
331000285844052090118522451455485
2000 KVA6,3-111025273047852265125022551525100020070310400372200
151080276548952270126021601430385
331185274549852270127524651635485
2500 KVA6,3-111420364563002395171023651625100020070310400 450330
151445363063002395171023801640385
331485362563452395141025251690485

1.5 mva transformer weight

PowerMax VoltageWeight of OilActive Section WeightTotal WeightLeng. AWid. BHeig. CDFØGLMNST
kVAkVkgkgkgmmmmmmmmmmmmmmmmmmmmmm
315 KVA6,3-11245820129515257501740103567015050310330 178150
152708401315154076017501040385330
332958501330160077518051105485350
400 KVA6,3-11255910136013707751595107067015050310265 138150
152909601460149577517101115385265
333359651525160077581551155485330
500 KVA6,3-11300110016016007601700115067015050310330 263150
1531511451690162577517651165385330
3338011751800167580519201220485350
630 KVA6,3-113501280190016807901785118567015050310330 263150
1534012851895164078517801185385330
3344014052135170081019451255485350
800 KVA6,3-114801530233518609451835119082015050310400 263150
1547515852385184592518701225385
3356016252515195092520001255485
1000 KVA6,3-115401760269019109901900133082020070310400340150
1556518402780191596519751330385
33650185529001950101520901360485
1250 KVA6,3-1168520703345205010102025138082020070310400340150
1567020803345201599520901400385
33760213034952005100522451455485
1600 KVA6,3-1182524154010210011302110142082020070310400 372200
15855254541552020112521101420385
331000285844052090118522451455485
2000 KVA6,3-111025273047852265125022551525100020070310400372200
151080276548952270126021601430385
331185274549852270127524651635485
2500 KVA6,3-111420364563002395171023651625100020070310400 450330
151445363063002395171023801640385
331485362563452395141025251690485

1500 kva transformer full load current

How to use the full load chart to find kVA

A) Determine the secondary voltage of your transformer.
B) Sum up the total amperes required by the load.
C) From the full load current table below, select a transformer under the corresponding secondary voltage, with a standard kVA capacity and amperage equal to or higher than the sum required by the load.

Full Load Current Table (1 Phase Transformer)

kVACurrent in Amperes
120V240V416V480V600V2400V4160V
0.252.081.040.60.520.41
0.54.162.081.21.040.83
0.756.253.131.81.561.25
18.334.172.42.081.67
1.512.56.253.63.132.5
216.78.334.814.173.33
32512.57.216.2551.250.72
541.620.81210.48.332.081.2
7.562.531.21815.612.53.121.8
1083.341.62420.816.64.162.4
1512562.53631.2256.253.6
25208104605241.610.46
37.531215690.178.162.515.69.01
5041620812010483.320.812
7562531218015612531.218
10083341624020816641.624
150125062536031225062.536
167139169540134727869.540.1
2502083104160052041610460
3332775138780069355513880

Single Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

HorsepowerFull Load Current (Amps)Minimum Transformer KVA
110-120V208V220-240V*
0.59.85.44.91.5
0.7513.87.66.92
1168.883
1.52011103
22413.2125
33418.7175
55630.8287.5
7.580444015
10100555015
1513574.86825
208825
2511037.5
3013637.5
4017650
5021675

kVA ratings include 10% overcapacity for frequent motor starts.

*For 200 volt motors, increase 220-240V ratings by 15%.

Full Load Current Table – 3 Phase Transformer?

kVACurrent in Amperes
208V240V380V416V480V600V2400V4160V
2 KVA5.554.813.032.772.41.920.480.27
3 KVA8.327.214.554.163.62.880.720.41
6 KVA16.614.49.118.327.215.771.440.83
9 KVA24.921.613.612.410.88.662.161.24
15 KVA41.63622.720.81814.43.62.08
30 KVA83.272.145.541.63628.87.214.16
45 KVA12410868.362.454.143.310.86.24
75 KVA20818011310490.272.11810.4
112.5 KVA3122701701561351082715.6
150 KVA4163602272081801443620.8
225 KVA62454134131227021654.131.2
300 KVA83272145541636028872.141.6
450 KVA1249108268362454143310862.4
500 KVA1387120275969360148112069.3
600 KVA1665144391183272157714483.2
750 KVA2081180411391040902721180104

Three Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

HorsepowerFull Load Current (Amps) MinimumTransformer kVA
110-120V208V220-240V*440-480V550-600V
0.542.2210.83
0.755.63.12.81.41.13
17.243.61.81.43
1.510.45.75.22.62.13
213.67.56.83.42.76
319.210.79.64.83.96
530.416.715.27.66.19
7.544242211915
10563128141115
15844642211730
201085954272230
251367568342745
301608880403245
40208114104524175
50260143130655275
60170154776275
752111929677112.5
10027324812499150

kVA ratings include 10% overcapacity for frequent motor starts.

* For 200 volt motors, increase 220-240V ratings by 15%.

1.5 mva transformer for sale

  • 1.5 mva transformer
  • 1500 kva transformer
  • transformer 1500 kva
  • 1500 kva dry type transformer
  • transformer 1500kva
  • 1500 kva pad mounted transformer
  • 1.5 mva oil filled transformer
  • 1500 kva oil filled transformer
  • 1.5 mva dry type transformer
  • 1500 kva transformer to kw
  • 1.5 mva pad mounted transformer
CPRI Aprroved transformer 1500 kva manufacturers, see 1500 kva dry type transformer weight and 1.5 mva transformer specification
ERDA Approved 1500 kva oil filled transformer suppliers, find here 1500 kva transformer full load current, 1500 kva transformer dimensions, 1.5 mva transformer weight