10 mva power transformer manufacturers in india
Prestige Quality 10/13 mva power transformer, 10 mva 33/11kv transformer suppliers in africa, view 10000 kva transformer price
The 10 mva 33/11kv transformer with a rated power up to 2.5 MVA and a voltage up to 36 kV are referred to as distribution transformers by the 10 mva transformer manufacturers in India . Typically, transformers which are known to have higher ratings are classified as 10 mva power transformer specifications.
10 mva power transformer manufacturers in india
10000 kva transformer
10/13 mva power transformer
World-Class 10 mva dry type transformer Exporter in india, view 10 mva transformer price and weight
To find out more about the cost of 10 mva transformer in india click here.All power ratings are the product of rated voltage, which is times phase-factor for three-phase transformers and the 10 mva transformer current rating of the line side winding which is at the centre tap, if several taps have been provided. As defined in IEC 76-1, the 10 mva transformer ratings have been expressed in kVA or MVA. Details of the 10000 kva transformer weight along with the 10 mva power transformer dimensions have been mentioned in the given link.
Electrical impedance like the 10 mva transformer impedance is the measure of the opposition which a circuit will presents to a current on application of a voltage. In other words, the effective resistance of an electric circuit or component such as the 10 mva power transformer to an alternating current, which arises from the combined effects of ohmic resistance as well as reactance. Find out more about the 10 mva transformer specification along with the dimensions and 10 mva power transformer weight.
A 10 mva dry type transformer belongs to a category of transformers which never uses any insulating liquid in instances where its winding or core have been immersed in liquid. Rather, the windings as well as the core of the dry type 8/10 mva transformer are generally kept within a sealed tank which has been pressurized with air.There are several benefits to using the 10 mva dry type transformer such as High mechanical strength, No temperature fluctuation, Easy maintenance, Void free insulation, Less prone to fire hazard.
Application | Power Transformer |
Basic Transformer Concept | oil-immersed, conservator tank |
Tank Design | Rigid tank, detachable cooling radiators |
Number of Phases | 3-phase |
Rated Power | 10 000 kVA |
Method of Cooling | ONAN |
Voltage Ratio | 33000/11000 V |
Tapping Range | 33 000 V +6×1,67% -9×1,67% |
Voltage Regulation | Motorized OLTC On-load tap changer in 16 steps |
Frequency | 50 Hz |
Temperature Rise (oil/wind) | 65/60 K |
Connection | Dyn11 |
Weight of Oil | ~7500 kg |
Transport Weight | ~16500 kg |
Total Weight | ~28000 kg |
10 mva transformer manufacturers in india export to | Uganda, Bangladesh, Rwanda, Africa, Tanzania, Nigeria, Nepal, India, Malaysia Kenya, Malawi |
Other Ratings | 10, 16, 25, 50, 63, 100, 160, 200, 315, 500, 630, 750 kVA |
all above transformer are | 11kV , 22kV, 33kV line |
Efficiency | 3, 4, 5 Star or Level II, Level III |
Volt amperes are a unit utilized to describe the electrical load in engineering. Volt amperes can be abbreviated VA. You can also utilize metric prefixes such as "kilo-" and "mega-." It takes 1,000 volt amperes to rise to one kilo-volt ampere and 1,000,000 volt-amperes to equal one mega-volt ampere. Therefore, it takes 1,000 kilo-volt amperes to get one mega-volt ampere. Divide the number of kVA by 1,000 to convert to MVA. For example, in case you’ve got 438 kVA, isolate 438 by 1,000 to get 0.438 MVA
We are one of the leading transformer manufacturer company catering to different segments that require continuous power supply.We realize the challenges faced by companies that depend on continuous supply of power for their operations. In case of transformer breakdown, we offer our transformers for beneficiary for brief power generation with step-up capabilities. Through our group of talented and proficient professionals, we guarantee fast arrangement and productive execution with no respectful alterations required.
10 MVA = 10000 KVA
For Final 10 MVA transformer price in india Please Mail Us on info@rajasthanpower.in
Request A Quote Today For 10 mva transformer at low cost, check 10 mva transformer current rating and dimensions
MVA stands for Mega Volt Amp or Volts X Amp /1000,000. In case your add up to load necessity is 1000 volts and 5000 amps (1000 x 5000 = 5000,000 VA) it can be communicated as 5MVA. Usually called "apparent power" since it takes into thought both the resistive load and the reactive load. We generally indicate load by MVA, KVA or VA as any specific appliance of power framework generally absorbs active power as well as reactive power. ( Eg: transformers).
Partition the number of kVA by 1,000 to convert to MVA. For illustration, in case you have got 438 kVA, isolate 438 by 1,000 to induce 0.438 MVA.Multiply the number of kVA by 0.001 to change over to MVA.
10 MVA = 10000 KVA
Below are the tests conducted by Rajasthan Powergen Transformer P. Ltd. before delivery. Other tests required by clients can also be done accordingly.
- Insulation resistance
- Resistance of all windings
- Check voltage ratio and vector group
- No-load test at rated frequency and rated voltage
- Impedance test
- Withstand voltage testing
- Induced over-voltage withstand testing
- Partial discharge measurement
- Oil leakage test
Transformer oil (moreover known as insulating oil) may be a uncommon type of oil which has fabulous electrical protection properties and is steady at high temperatures. Transformer oil is utilized in oil-filled electrical power transformers to insulate, stop arcing and corona release, and to disseminate the heat of the transformer (i.e. act as a coolant).
Main Technical Parameters for 35KV level ,S11 series distribution transformer | ||||||
Rated Power (kva) |
High Voltage (kv) |
H.V.Tap range |
Low Voltage (kv) |
Connection symbol |
No-load loss(W) | On-load loss(W) |
2000 kva | 35 |
±3*2.5 |
6.3
10.5 |
Ynd11 | 2.31 | 19.24 |
2500 kva | 2.72 | 20.65 | ||||
3150 kva |
35
38.5 |
3.24 | 24.71 | |||
4000 kva | 3.88 | 29.12 | ||||
5000 kva | 4.64 | 34.2 | ||||
6300 kva | 5.64 | 36.8 | ||||
8000 kva |
6.3
6.6
10.5
11 |
Ynd11 | 7.88 | 40.62 | ||
10000 kva | 9.28 | 48.05 | ||||
12500 kva | 10.95 | 57.81 | ||||
16000 kva | 13.16 | 70.32 | ||||
20000 kva | 15.57 | 82.8 | ||||
25000 kva | 18.07 |
The impedance of a transformer is the entire restriction offered to substituting current. This may be calculated for each winding.However, a rather basic test gives a practical strategy of measuring the comparable impedance of a transformer without isolating the impedance of the windings.
Calculation of Percentage Impedance
In arrange to decide proportionate impedance, one winding of the transformer is short-circuited. And a fair sufficient voltage is connected to the other winding to make full load current to stream within the short-circuited winding.This voltage is known as the impedance voltage.
Impedance Data for Single-Phase Transformers
kVA |
Suggested X/R Ratio |
Normal Range of Percent |
Impedance Multipliers** For Line-to-Neutral |
|
1Ø |
Calculation |
|
for %X |
for %R |
25.0 kva |
1.1 |
1.2–6.0 |
0.6 |
0.75 |
37.5 kva |
1.4 |
1.2–6.5 |
0.6 |
0.75 |
50.0 kva |
1.6 |
1.2–6.4 |
0.6 |
0.75 |
75.0 kva |
1.8 |
1.2–6.6 |
0.6 |
0.75 |
100.0 kva |
2.0 |
1.3–5.7 |
0.6 |
0.75 |
kVA stands for Kilovolt-Ampere and is the rating regularly utilized to rate a transformer. The size of a transformer is decided by the kVA of the load. In numerous circumstances the power required by the load is proportionate to the rating of the transformer communicated in either VA or kVA. For case a 1KW (1000 Watts) load would require a 1kVA transformer @ unity power factor.
KVA calculation
For three phase KVA= (V*I*1.732)/1000
For single phase KVA= (V*I)/1000
MVA calculation-
For three phase MVA= (V*I*1.732)/100,000
For single phase MVA= (V*I)/1000,000
|
|