Rajasthan power

10 MVA distribution transformer manufacturers

Prestige Quality 10/13 mva power transformer, 10 mva 33/11kv transformer suppliers in africa, view 10000 kva transformer price
10-mva-power-transformer-manufacturers-in-india

The 10 mva 33/11kv transformer with a rated power up to 2.5 MVA and a voltage up to 36 kV are referred to as distribution transformers by the 10 mva transformer manufacturers in India . Typically, transformers which are known to have higher ratings are classified as 10 mva power transformer specifications.

10 mva power transformer manufacturers in india

10 mva power transformer manufacturers in india

10000 kva transformer

10000 kva transformer

10/13 mva power transformer

10/13 mva power transformer

World-Class 10 mva dry type transformer Exporter in india, view 10 mva transformer price and weight

To find out more about the cost of 10 mva transformer in india click here.All power ratings are the product of rated voltage, which is times phase-factor for three-phase transformers and the  10 mva transformer current rating of the line side winding which is at the centre tap, if several taps have been provided. As defined in IEC 76-1, the  10 mva transformer ratings have been expressed in kVA or MVA. Details of the 10000 kva transformer weight along with the 10 mva power transformer dimensions have been mentioned in the given link.

Electrical impedance like the 10 mva transformer impedance is the measure of the opposition which a circuit will presents to a current on application of a voltage. In other words, the effective resistance of an electric circuit or component such as the 10 mva power transformer to an alternating current, which arises from the combined effects of ohmic resistance as well as reactance. Find out more about the 10 mva transformer specification along with the dimensions and 10 mva power transformer weight.

10 mva dry type transformer belongs to a category of transformers which never uses any insulating liquid in instances where its winding or core have been immersed in liquid. Rather, the windings as well as the core of the dry type 8/10 mva transformer are generally kept within a sealed tank which has been pressurized with air.There are several benefits to using the 10 mva dry type transformer such as High mechanical strength, No temperature fluctuation, Easy maintenance, Void free insulation, Less prone to fire hazard.

what is 10 mva transformer ?

Volt amperes are a unit utilized to describe the electrical load in engineering. Volt amperes can be abbreviated VA. You can also utilize metric prefixes such as “kilo-” and “mega-.” It takes 1,000 volt amperes to rise to one kilo-volt ampere and 1,000,000 volt-amperes to equal one mega-volt ampere. Therefore, it takes 1,000 kilo-volt amperes to get one mega-volt ampere. Divide the number of kVA by 1,000 to convert to MVA. For example, in case you’ve got 438 kVA, isolate 438 by 1,000 to get 0.438 MVA

We are one of the leading transformer manufacturer company catering to different segments that require continuous power supply.We realize the challenges faced by companies that depend on continuous supply of power for their operations. In case of transformer breakdown, we offer our transformers for beneficiary for brief power generation with step-up capabilities. Through our group of talented and proficient professionals, we guarantee fast arrangement and productive execution with no respectful alterations required.

10 MVA = 10000 KVA

10 mva power transformer specifications

ApplicationPower Transformer
Basic Transformer Conceptoil-immersed, conservator tank
Tank DesignRigid tank, detachable cooling radiators
Number of Phases3-phase
Rated Power10 000 kVA
Method of CoolingONAN
Voltage Ratio33000/11000 V
Tapping Range33 000 V +6×1,67% -9×1,67%
Voltage RegulationMotorized OLTC On-load tap changer in 16 steps
Frequency50 Hz
Temperature Rise (oil/wind)65/60 K
ConnectionDyn11
Weight of Oil~7500 kg
Transport Weight~16500 kg
Total Weight~28000 kg
10 mva transformer manufacturers in india export toUganda, Bangladesh, Rwanda, Africa, Tanzania, Nigeria, Nepal, India, Malaysia Kenya, Malawi
Other Ratings10, 16, 25, 50, 63, 100, 160, 200, 315, 500, 630, 750 kVA
all above transformer are11kV , 22kV, 33kV line
Efficiency3, 4, 5 Star or Level II, Level III

10000 kva transformer price

 For Final 10 MVA transformer price in india Please Mail Us on info@rajasthanpower.in

10 mva transformer manufacturers in india

Request A Quote Today For 10 mva transformer at low cost, check 10 mva transformer current rating and dimensions

10 mva to kva

MVA stands for Mega Volt Amp or Volts X Amp /1000,000. In case your add up to load necessity is 1000 volts and 5000 amps (1000 x 5000 = 5000,000 VA) it can be communicated as 5MVA. Usually called “apparent power” since it takes into thought both the resistive load and the reactive load. We generally indicate load by MVA, KVA or VA as any specific appliance of power framework generally absorbs active power as well as reactive power. ( Eg: transformers).

Partition the number of kVA by 1,000 to convert to MVA. For illustration, in case you have got 438 kVA, isolate 438 by 1,000 to induce 0.438 MVA.Multiply the number of kVA by 0.001 to change over to MVA.

10 MVA = 10000 KVA

10 mva transformer current rating

kVA stands for Kilovolt-Ampere and is the rating regularly utilized to rate a transformer. The size of a transformer is decided by the kVA of the load. In numerous circumstances the power required by the load is proportionate to the rating of the transformer communicated in either VA or kVA. For case a 1KW (1000 Watts) load would require a 1kVA transformer @ unity power factor.

KVA calculation
For three phase KVA= (V*I*1.732)/1000
For single phase KVA= (V*I)/1000

MVA calculation-
For three phase MVA= (V*I*1.732)/100,000
For single phase MVA= (V*I)/1000,000

Get All Type Test Report Here

5 MVA Lightning Impulse Test Report5 MVA Short circuit Test Report5 MVA Temperature Rise Test Report
3.15 MVA Lightning Impulse Test Report3.15 MVA Short Circuit Test Report3.15 MVA Temperature Rise Test Report
2000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report1000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Paint Adhesion Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Sound Power Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report160 KVA, Lightning Impulse Test Report
160 KVA, Short Circuit Test Report160 KVA, Temperature Rise Test Report100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Lightning Impulse Test Report
100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Short Circuit Test Report100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Sound Power Test Report100 KVA Aluminium Wound Distribution Transformer Temperature Rise Test Report
63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Sound Power Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report
10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test ReportSingle Phase 25 KVA ALuminium wound Distribution Transformer EEL-2Single Phase 16 KVA ALuminium wound Distribution Transformer EEL-2
Single Phase 10 KVA ALuminium wound Distribution Transformer EEL-2Single Phase 5 KVA Aluminium wound Distribution Transformer EEL-2Single Phase 5 KVA Copper wound Distribution Transformer EEL-2

types of industrial transformer available

10 mva transformer dimensions

Main Technical Parameters for 35KV level ,S11 series distribution transformer
Rated
Power
(kva)
High
Voltage
(kv)
H.V.Tap
range
Low
Voltage
(kv)
Connection
symbol
No-load loss(W)On-load loss(W)
2000 kva   35   ±3*2.5

   6.3

10.5

     Ynd11     2.31     19.24
2500 kva     2.72     20.65
3150 kva

   35

38.5

     3.24     24.71
4000 kva      3.88     29.12
5000 kva      4.64     34.2
6300 kva      5.64     36.8
8000 kva

    6.3

6.6

10.5

11

    Ynd11      7.88     40.62
10000 kva      9.28     48.05
12500 kva      10.95     57.81
16000 kva      13.16     70.32
20000 kva     15.57      82.8
25000 kva      18.07

10000 kva transformer weight

5-mva-transformer-weight

10 mva transformer testing

Below are the tests conducted by Rajasthan Powergen Transformer P. Ltd. before delivery. Other tests required by clients can also be done accordingly.

  •  Insulation resistance
  •  Resistance of all windings
  •  Check voltage ratio and vector group
  • No-load test at rated frequency and rated voltage
  • Impedance test
  • Withstand voltage testing
  • Induced over-voltage withstand testing
  • Partial discharge measurement
  • Oil leakage test

10 mva transformer impedance

The impedance of a transformer is the entire restriction offered to substituting current. This may be calculated for each winding.However, a rather basic test gives a practical strategy of measuring the comparable impedance of a transformer without isolating the impedance of the windings.

Calculation of Percentage Impedance

In arrange to decide proportionate impedance, one winding of the transformer is short-circuited. And a fair sufficient voltage is connected to the other winding to make full load current to stream within the short-circuited winding.This voltage is known as the impedance voltage.

calculation-of-percentage-impedance

Impedance Data for Single-Phase Transformers

kVASuggested X/R Ratio
for
Normal Range of Percent
Impedance (%Z)*
Impedance Multipliers** For Line-to-Neutral
Faults
Calculation for %Xfor %R

25.0 kva

1.11.2–6.00.60.75

37.5 kva

1.41.2–6.50.60.75

50.0 kva

1.61.2–6.40.60.75

75.0 kva

1.81.2–6.60.60.75
100.0 kva2.01.3–5.70.60.75

10 mva transformer oil capacity

Transformer oil (moreover known as insulating oil) may be a uncommon type of oil which has fabulous electrical protection properties and is steady at high temperatures. Transformer oil is utilized in oil-filled electrical power transformers to insulate, stop arcing and corona release, and to disseminate the heat of the transformer (i.e. act as a coolant).

transformer-oil

10 mva transformer for sale

  • 10000 kva transformer
  • 10 mva transformer
  • 10 mva power transformer
  • 10 mva dry type transformer
  • 10 mva 33/11kv transformer
CPRI Aprroved 10 mva 33/11kv transformer manufacturers , see 10 mva power transformer specifications
ERDA Approved  10 mva power transformer manufacturers in india, get cost of 10 mva transformer in india and 10 mva transformer oil capacity