A Full Range Of CPRI approved transformers suppliers in africa, view CPRI approved transformers price
Central Power Research Institute is also known as CPRI in short. CPRI has been established in 1960 by the Government of India. CPRI or Central Power Research Institute is a Premier Institute which undertakes applied Research in the field of electrical engineering besides operating as an Independent National Testing as well as Certification authority for electrical equipment in India. One such product tested by the Central Power Research Institute is a transformer.
At Rajasthan Powergen Transformer P. Ltd., We are a factory that has been cpri approved transformers for various fields such as distributors transformers, power transformers, current transformers, reactors as well as voltage transformers. Since we are cpri approved transformers manufacturers, the reactors & transformers, produced in our factory have been tested periodically for both Impulse as well as Short circuit withstand. With regards to Distribution and Power Transformers, the tests administered according to the Central Power Research Institute standards include Short circuit dynamic and thermal withstands test.
Generally, the cpri approved transformers are tested with Short circuit tests up to 200 kArm or a 1100 Volts for LT equipment has been used or Short time current tests up to 200 kArms for one second or 100 kArms for a period of 3 seconds.As one of the leading cpri approved transformers manufacturers, we have facilities to test and check our products at regular intervals.We are one of the leading and certified dealers, suppliers and distributors along with being a cpri approved transformers manufacturers in Mumbai.
CPRI. Central Power Research Institute (CPRI) was set up by the Government of India in 1960. It could be a Head Established undertaking applied Research in electrical engineering other than working as an Autonomous National Testing and Certification authority for electrical equipment.it got to be an Independent Society within the year 1978 beneath the aegis of the Ministry of Power, Government of India. The Institute has advertised its services for more than five decades to the Power Sector.
Classification of Transformer | Range | Type |
Power Transformer | 3.15 MVA to 150 MVA at 330 KV class | Core type 3 phase, Generator Transformer, Unit Auxiliary Transformers, Step up and step down Transformers, Interconnecting. Auto Transformers, Dual Voltage Primary or Secondary Three winding Transformers. |
Distribution Transformer | 6.3 KVA to 3150 KVA, upto 33 KV classs | Core type single phase, Three winding Transformers, Step up and step down Transformers, Dual Voltage Primary or Secondary. |
Special Transformers | As per customer requirement | Auto Transformers, Arc Furnace Transformers, Step up Generator Transformers, Thyristor Duty Transformers, Zig zag Transformers, Voltage Regulators,Earthing Transformer,Rectifier Transformer,Mining Transformer,Testing Transformer,Transformer for AC/DC Drives.r |
Rajasthan Powergen Transformer P. Ltd. test our products in CPRI and get the test certificates. CPRI Certificates are widely accepted in many countries. The main reasons for such wide acceptance apart from good testing infrastructure and expertise are national/international accreditations like:
For Final CPRI approved transformers price india Please Mail Us on info@rajasthanpower.in
Testing is one of the critical capacities of the transformer fabricating action.
Following are the Tests that are carried out on the transformers before they are ready for final delivery:
a | Routine tests |
---|---|
1 | Oil Dielectric Strength (BDV) Test |
2 | Core cutting & assembly |
3 | Measurement of Voltage Ratio |
4 | Check of polarity and phase displacement |
5 | Magnetizing current |
6 | Short circuit current |
7 | Magnetic Balance |
8 | Winding resistance |
9 | Measurement of short-circuit impedance and load loss |
10 | Measurement of no-load loss and current |
11 | Separate source AC withstand voltage test |
12 | Short duration induced AC withstand voltage test |
13 | Pressure & Oil Leakage Tests |
b | Type tests |
14 | Impulse Test |
15 | Lightning & Switching Impulse test |
c | Special tests |
16 | Zero-sequence impedance |
17 | Capacitance & Tan delta of Bushing |
18 | Capacitance & Tan delta of Windings |
19 | Noise level measurement |
All the Testing is carried as per latest IS Standards
Description | Max Ratings | Voltages | Standards |
Amorphous Metal Cores Distribution Transformers | 2.5 MVA | Up to 11kV | ANSI,IEC,IS |
Cast Resin Dry Type | 1 MVA | Up to 11kV | ANSI,IEC,IS |
Conventional Oil Cooled Distribution Transformers | 5 MVA | Up to 36 kV | ANSI,IEC,IS |
Corrugated Tank Oil Cooled Transformers | 2.5 MVA | Up to 36 kV | ANSI,IEC,IS |
Single-phase Pole mount Distribution Transformers | 315 kVA | Up to 36 kV | ANSI,IEC,IS |
Three-phase Pole or Platform Type Transformers | 5 MVA | Up to 36 kV | ANSI,IEC,IS |
Solar Application Inverter Transformer | 5 MVA | Up to 36 kV | ANSI,IEC,IS |