Rajasthan power

2.5 MVA distribution transformer manufacturers

2500 kva transformer manufacturers in india, view 2.5 mva transformer price, A Full Range Of 2.5 mva power transformer suppliers in africa.

2.5-mva-transformer-manufacturers

The 2500 kva dry type transformer specifications are widely used in – Environmentally sensitive areas (e.g. water protection areas), Chemical, oil and gas industry, Inner-city substations, Indoor and underground substations, Fire-risk areas (e.g. forests) as well as in Renewable generation (e.g. off-shore wind turbines).

2.5 mva transformer manufacturers in india

2.5 mva transformer manufacturers in india

2500 kva transformer manufacturers in india

2500 kva transformer manufacturers in india

2500 kva pad mount transformer

2 mva dry type transformer

Carries A Complete Line Of 2.5 mva dry type transformer, 2.5 mva transformer Exporter in india, view 2500 kva transformer price in india.

Click here for the 2500 kva transformer price in India. We are one of the leading suppliers as well as 2500 kva transformer manufacturers in India. Learn more about the 2.5 mva transformer weight as well as the 2500 kva oil filled transformer dimensions here.

A pad mount or a 2500 kva pad mount transformer is a kind of a ground mounted electric power distribution transformer. This pad mounted 2500 kva pad mounted transformer has been locked in a steel cabinet and mounted on a concrete pad. Since all energized connection points in the 2500 kva transformer amps  have been securely enclosed in a grounded metal housing, these 2500 kva pad mount transformer dimensions can be installed in places which do not have room for a fenced enclosure. Pad mount 2.5 mva transformer impedance could used with underground electric power distribution lines at service drops.

These 2500 kva transformer specifications are used to step down the primary voltage on the line to the lower secondary voltage, which is then supplied to utility customers. A single 2.5 mva transformer could be used to serve one large building, or many homes. Check the cost of 2.5 mva transformer here. You can find more details on the 2500 kva transformer for sale in the link given here. We customise 2.5 mva transformer nameplate details as required by the buyer. For more details on the 2.5 mva transformer oil capacity click the link given.

The pad mounted 2.5 mva transformer current rating are made in power ratings from around 75 kVA to around 5000 kVA. The 2.5 mva transformer manufacturers in india often include built-in fuses and switches. Click here to inquire about the 2500 kva pad mount transformer weight.  Primary power cables of the 2.5 mva power transformer may be connected with elbow connectors, which in turn could be operated when energized using a hot stick. This operation in the 2.5 mva dry type transformer allows for flexibility in repair and maintenance.

what is 2.5 mva power transformer ?

MVA stands for Mega Volt Amp or Volts X Amp /1000,000. In the event that your total load necessity is 1000 volts and 5000 amps (1000 x 5000 = 5000,000 VA) it can be expressed as 5MVA.Auto transformers have the advantage of being littler and cheaper than twofold wound transformers. We will make essentially any estimate of single or 3 phase transformer, dependant on voltage.

We manufacture transformers for a wide extend of industries,if you’ve got particular prerequisites for your 3 phase transformers at that point please request a cite along with your points of interest or get in touch via phone, we’re here to assist!

2.5 MVA = 2500kVA

2500 kva transformer specifications

Rating2.5MVA, 3PH, 415/6.6/11KV
Frequency50 HZ
LT Nominal Voltage415V, AC
LT Breaker4000A, 3P, 415V MDO
HT Nominal Voltage6.6/11KV, AC
CT Ratio100/5A
PT Ratio11/110V
Capacity of Oil250 LTR
Type of OilTC OIL
Vector GroupY-Y
Empty Weight8000KG
Full Weight7500KG
ProvisionsCan For Step Up and Step Down Application for Step Down Application Load Should be Balanced on 3PH
2.5 mva transformer manufacturers export toAfrica, Bangladesh, Rwanda, Malaysia Tanzania, Nigeria, Kenya, Uganda, India, Malawi, Nepal
Other Ratings10, 16, 25, 50, 63, 100, 160, 200, 315, 500, 630, 750 kVA
all above transformer are11kV , 22kV, 33kV line
Efficiency3, 4, 5 Star or Level II, Level III

2.5 mva transformer price

For Final 2500 kva transformer price in india Please Mail Us on info@rajasthanpower.in

2.5 mva transformer manufacturers in india

India’s Largest Manufacturer Of 2500 kva pad mount transformer, Check 2.5 mva transformer oil capacity and cost of 2.5 mva transformer

2.5 mva transformer impedance

The impedance of a transformer is the entire restriction offered to substituting current. This may be calculated for each winding.However, a rather basic test gives a practical strategy of measuring the comparable impedance of a transformer without isolating the impedance of the windings.

Calculation of Percentage Impedance

In arrange to decide proportionate impedance, one winding of the transformer is short-circuited. And a fair sufficient voltage is connected to the other winding to make full load current to stream within the short-circuited winding.This voltage is known as the impedance voltage.

calculation-of-percentage-impedance

Impedance Data for Single-Phase Transformers

 

kVA

Suggested X/R Ratio
for
Normal Range of Percent
Impedance (%Z)*
Impedance Multipliers** For Line-to-Neutral
Faults
Calculation for %Xfor %R

25.0

1.11.2–6.00.60.75

37.5

1.41.2–6.50.60.75

50.0

1.61.2–6.40.60.75

75.0

1.81.2–6.60.60.75
100.02.01.3–5.70.60.75

Main Technical Parameters

Rated
Power
(kVA)
High
Voltage
(kV)
H.V. Tap
Range
Low
Voltage
(kV)
Connection
Symbol
Short
Circuit
Impedance
(%)
No-load Loss (W)On-load Loss (W)No Load
Current (%)
3020
22
±5%
±2×2.5%
0.4Yyn0
Dyn11
41006002.1
501308702
6315010401.9
8018012501.8
10020015001.6
12524018001.5
16029022001.4
20033026001.2
25040030501.2
31548036501.1
40057043001
50068051501
6304.581062000.9
80098075000.8
10001150103000.7
12501360120000.6
16001640145000.6
20001940171000.6
25002300202600.5

2.5 mva transformer current rating

kVA stands for Kilovolt-Ampere and is the rating regularly utilized to rate a transformer. The size of a transformer is decided by the kVA of the load. In numerous circumstances the power required by the load is proportionate to the rating of the transformer communicated in either VA or kVA. For case a 1KW (1000 Watts) load would require a 1kVA transformer @ unity power factor.

KVA calculation
For three phase KVA= (V*I*1.732)/1000
For single phase KVA= (V*I)/1000

MVA calculation-
For three phase MVA= (V*I*1.732)/100,000
For single phase MVA= (V*I)/1000,000

Get All Type Test Report Here

5 MVA Lightning Impulse Test Report5 MVA Short circuit Test Report5 MVA Temperature Rise Test Report
3.15 MVA Lightning Impulse Test Report3.15 MVA Short Circuit Test Report3.15 MVA Temperature Rise Test Report
2000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report1000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Paint Adhesion Test Report500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Sound Power Test Report315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report160 KVA, Lightning Impulse Test Report
160 KVA, Short Circuit Test Report160 KVA, Temperature Rise Test Report100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Lightning Impulse Test Report
100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Short Circuit Test Report100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Sound Power Test Report100 KVA Aluminium Wound Distribution Transformer Temperature Rise Test Report
63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Sound Power Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report
10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test ReportSingle Phase 25 KVA ALuminium wound Distribution Transformer EEL-2Single Phase 16 KVA ALuminium wound Distribution Transformer EEL-2
Single Phase 10 KVA ALuminium wound Distribution Transformer EEL-2Single Phase 5 KVA Aluminium wound Distribution Transformer EEL-2Single Phase 5 KVA Copper wound Distribution Transformer EEL-2

types of industrial transformer available

2500 kva transformer oil capacity

Transformer oil (moreover known as insulating oil) may be a uncommon type of oil which has fabulous electrical protection properties and is steady at high temperatures. Transformer oil is utilized in oil-filled electrical power transformers to insulate, stop arcing and corona release, and to disseminate the heat of the transformer (i.e. act as a coolant).

Main Dimensions of the 300-2500 kVA Standard Transformers with Oil Expansion Tanks
PowerMax VoltageWeight of OilActive Section WeightTotal WeightLeng. AWid. BHeig. CDFØGLMNST
kVAkVkgkgkgmmmmmmmmmmmmmmmmmmmmmm
25006,3-111420364563002395171023651625100020070310400 450330
151445363063002395171023801640385
331485362563452395141025251690485
transformer-oil

2500 kva pad mount transformer dimensions

Continuous Current Rating (A)8.3 kV9.9 kV15.5 kV
Minimum Interrupting Capacity (A)Minimum Melt I2t (A2•s)Maximum Clear I2t (A2•s)Minimum Interrupting Capacity (A)Minimum Melt I2t (A2•s)Maximum Clear I2t (A2•s)Minimum Interrupting Capacity (A)Minimum Melt I2t (A2•s)Maximum Clear I2t (A2•s)
30

200

1,800

9,400

200

1,800

9,500

200

1,800

10,000

40

250

2,900

14,000

250

2,900

14,000

250

2,900

19,000

50

330

6,300

30,000

330

6,300

30,000

330

6,300

33,000

65

400

9,300

33,000

400

9,300

34,000

400

9,300

40,000

80

300

11,600

56,000

30011,600

56,000

350

11,600

62,000

100

450

20,600

76,000

45020,600

76,000

450

20,600

116,000

125

470

32,100

120,000

   500

32,100

150,000

150

700

58,500

290,000

   700

58,500

260,000

165

800

82,200

395,000

   800

82,200

365,000

180

900

103,100

485,000

   900103,100

445,000

2501,000148,500

690,000

      
250 1      1100128,500

500,000

300 11,300234,2001,280,000   1230234,2001,300,000
330 11,500328,9001,700,000      
360 11,800412,5002,100,000      
500 12,000594,0002,500,000 
Continuous Current Rating (A)17.2 kV23 kV38 kV
Minimum Interrupting Capacity (A)Minimum Melt I2t (A2•s)Maximum Clear I2t (A2•s)Minimum Interrupting Capacity (A)Minimum Melt I2t (A2•s)Maximum Clear I2t (A2•s)Minimum Interrupting Capacity (A)Minimum Melt I2t (A2•s)Maximum Clear I2t (A2•s)
30

200

1,800

10,000

200

1,800

12,000

   
40

250

2,900

19,500

250

2,900

20,000

   
50

330

6,300

34,000

330

6,300

39,000

450

3,870

30,600

65

400

9,300

42,000

400

9,300

44,000

490

7,160

39,300

80

350

11,600

62,000

30011,600

70,000

62511,450

60,700

100

450

20,600

116,000

45020,600

120,000

63516,100

80,500

120      70021,200

118,000

125

500

32,100150,00046532,100

180,000

   
140      80036,240

163,000

150   70058,500

320,000

   
165   90082,200

430,000

   
250 1   900128,500

650,000

   
300 1   1200234,2001,300,000   
330 1   1500328,9001,700,000 

2500 kva transformer weight

werMax VoltageWeight of OilActive Section WeightTotal WeightLeng. AWid. BHeig. CDFØGLMNST
kVAkVkgkgkgmmmmmmmmmmmmmmmmmmmmmm
315 KVA6,3-11245820129515257501740103567015050310330 178150
152708401315154076017501040385330
332958501330160077518051105485350
400 KVA6,3-11255910136013707751595107067015050310265 138150
152909601460149577517101115385265
333359651525160077581551155485330
500 KVA6,3-11300110016016007601700115067015050310330 263150
1531511451690162577517651165385330
3338011751800167580519201220485350
630 KVA6,3-113501280190016807901785118567015050310330 263150
1534012851895164078517801185385330
3344014052135170081019451255485350
800 KVA6,3-114801530233518609451835119082015050310400 263150
1547515852385184592518701225385
3356016252515195092520001255485
1000 KVA6,3-115401760269019109901900133082020070310400340150
1556518402780191596519751330385
33650185529001950101520901360485
1250 KVA6,3-1168520703345205010102025138082020070310400340150
1567020803345201599520901400385
33760213034952005100522451455485
1600 KVA6,3-1182524154010210011302110142082020070310400 372200
15855254541552020112521101420385
331000285844052090118522451455485
2000 KVA6,3-111025273047852265125022551525100020070310400372200
151080276548952270126021601430385
331185274549852270127524651635485
2500 KVA6,3-111420364563002395171023651625100020070310400 450330
151445363063002395171023801640385
331485362563452395141025251690485

2500 kva transformer full load current

How to use the full load chart to find kVA

A) Determine the secondary voltage of your transformer.
B) Sum up the total amperes required by the load.
C) From the full load current table below, select a transformer under the corresponding secondary voltage, with a standard kVA capacity and amperage equal to or higher than the sum required by the load.

Full Load Current Table (1 Phase Transformer)

kVACurrent in Amperes
120V240V416V480V600V2400V4160V
0.252.081.040.60.520.41
0.54.162.081.21.040.83
0.756.253.131.81.561.25
18.334.172.42.081.67
1.512.56.253.63.132.5
216.78.334.814.173.33
32512.57.216.2551.250.72
541.620.81210.48.332.081.2
7.562.531.21815.612.53.121.8
1083.341.62420.816.64.162.4
1512562.53631.2256.253.6
25208104605241.610.46
37.531215690.178.162.515.69.01
5041620812010483.320.812
7562531218015612531.218
10083341624020816641.624
150125062536031225062.536
167139169540134727869.540.1
2502083104160052041610460
3332775138780069355513880

Single Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

HorsepowerFull Load Current (Amps)Minimum Transformer KVA
110-120V208V220-240V*
0.59.85.44.91.5
0.7513.87.66.92
1168.883
1.52011103
22413.2125
33418.7175
55630.8287.5
7.580444015
10100555015
1513574.86825
208825
2511037.5
3013637.5
4017650
5021675

kVA ratings include 10% overcapacity for frequent motor starts.

*For 200 volt motors, increase 220-240V ratings by 15%.

Full Load Current Table – 3 Phase Transformer?

kVACurrent in Amperes
208V240V380V416V480V600V2400V4160V
2 KVA5.554.813.032.772.41.920.480.27
3 KVA8.327.214.554.163.62.880.720.41
6 KVA16.614.49.118.327.215.771.440.83
9 KVA24.921.613.612.410.88.662.161.24
15 KVA41.63622.720.81814.43.62.08
30 KVA83.272.145.541.63628.87.214.16
45 KVA12410868.362.454.143.310.86.24
75 KVA20818011310490.272.11810.4
112.5 KVA3122701701561351082715.6
150 KVA4163602272081801443620.8
225 KVA62454134131227021654.131.2
300 KVA83272145541636028872.141.6
450 KVA1249108268362454143310862.4
500 KVA1387120275969360148112069.3
600 KVA1665144391183272157714483.2
750 KVA2081180411391040902721180104

Three Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

HorsepowerFull Load Current (Amps) MinimumTransformer kVA
110-120V208V220-240V*440-480V550-600V
0.542.2210.83
0.755.63.12.81.41.13
17.243.61.81.43
1.510.45.75.22.62.13
213.67.56.83.42.76
319.210.79.64.83.96
530.416.715.27.66.19
7.544242211915
10563128141115
15844642211730
201085954272230
251367568342745
301608880403245
40208114104524175
50260143130655275
60170154776275
752111929677112.5
10027324812499150

kVA ratings include 10% overcapacity for frequent motor starts.

* For 200 volt motors, increase 220-240V ratings by 15%.

2.5 mva transformer Main Functions and Features

  • The winding has novel structure and its oil passage is reasonable designed. Its newly designed insulation structure helps enhance its mechanical strength and the short circuit withstanding ability.
  • The oil tank is in various types, all have good outlook.
  • The core joints are of stepped shape with 3 steps, and the surface of the core is coated with cured paint to lower losses and noise.
  • High reliability, advanced level of performances, reasonable economical indicators.

2500 kva transformer amps

Formulas Used In Calculation:

1-Phase KVA = Volts x Amps / 1000
1-Phase Amps = KVA / Volts x 1000
3-Phase KVA = Volts x Amps x 1.732 / 1000
3-Phase Amps = KVA / Volts / 1.732 x 1000

Generator KVA Rating to Amperage Conversion Chart
80% POWER FACTOR
kV•AkW208V220V240V380V440V480V600V2400V3300V4160V
6.3 KVA517.516.515.29.68.37.66.1   
9.4 KVA7.526.124.722.614.312.311.39.1   
12.5 KVA1034.73330.119.216.615.112   
18.7 KVA155249.54528.824.922.518   
25 KVA2069.56660.238.433.230.12464.43.5
31.3 KVA258782.575.54841.537.8307.55.54.4
37.5 KVA301049990.357.649.845.2369.16.65.2
50 KVA401391321207766.5604812.18.87
62.5 KVA501731651529683766115.110.98.7
75 KVA6020819818111599.5917218.113.110.5
93.8 KVA752612472261431231139022.616.413
100 KVA802782642401541331209624.117.613.9
125 KVA1003473303011921661501203021.817.5
156 KVA1254334133752402081881503827.322
187 KVA150520495450288249225180453326
219 KVA175608577527335289264211533831
250 KVA200694660601384332301241604435
312 KVA250866825751480415376300755543
375 KVA3001040990903576498451361906652
438 KVA3501220115510536725815274221057761
500 KVA4001390132012037706656024811208869
625 KVA50017351650150496083075260215010987
750 KVA6002080198018031150996902721180131104
875 KVA700243023102104134412741052842210153121
1000 KVA800278026402405154013301203962241176139
1125 KVA9003120297027091730149513541082271197156
1250 KVA10003470330030091920166015041202301218174
1563 KVA12504350413037402400208018851503376273218
1875 KVA15005205495045202880249022601805452327261
2188 KVA1750  52803350289026402106528380304
2500 KVA2000  60203840332030152405602436348
2812 KVA2250  67804320373534002710678491392
3125 KVA2500  75204800416037403005752546435
3750 KVA3000  90405760498045253610904654522
4375 KVA3500  1055067005780528542201055760610
5000 KVA4000  1204076806640603548101204872695

2500 kva transformer for sale

  • 2.5 mva transformer
  • 2500 kva transformer
  • 2.5 mva power transformer
  • 2.5 mva dry type transformer
  • 2500 kva pad mount transformer
  • 2500 kva oil filled transformer
  • 2.5 mva transformer oil capacity
  • 2500 kva dry type transformer
  • 2500 kva transformer full load current
Buy 2500 kva pad mounted transformer at low cost, get 2500 kva oil filled transformer dimensions, specifications and weight
Contact For 2.5 mva transformer buy online, find here 2500 kva transformer oil capacity,2.5 mva transformer nameplate details and 2.5 mva transformer impedance