Environment Friendly Transformer
An Authorized Eco Friendly Power Transformer suppliers in africa, view Environmentally Friendly Transformer Oil price
Green transformers or environmental transformers is a concept which demonstrates a new way to the customers who want to preserve the environment. These environment friendly transformer work towards offering not only a lower carbon footprint, but also limiting the risk of pollution and optimising life cycle costs, thereby leading to a lesser maintenance.
- What is Environment Friendly Transformer ?
- Eco Friendly Power Transformer specification
- Eco-Friendly Transformers price
- Eco-friendly ester liquid transformer designs
- Comparison between vegetable-oil based transformer and mineral insulating oil transformer
- Environment Friendly Transformer functionalities
- Environment Friendly Transformer Technical Data
- Eco Friendly Power Transformer Testing
- Eco Friendly Power Transformer Key Advantages
Environment Friendly Transformer
Eco Friendly Power Transformer
Green Transformers
Looking For Environmentally friendly cast resin transformers Exporter in india, view Green Transformers price
Other advantages of the eco friendly power transformer include lower noise levels, reduced ageing, increased fire safety as well as reliability. For instance, the level of noise reduction above 10 dB (A) is made possible due to a combination of things such as the selection of materials which tend to deliver a higher performance and equipment, along with the optimised design of active parts and innovative mechanical structures as well.
In terms of its safety and reliability, the environment friendly transformer generally offers an increase in shelf life while being safe. By using a Green Power environment friendly transformer, fire safety is an aspect that has been improved considerably. Thus, these green transformers not only offer an increase in security, for operators but also for those in close proximity. Ester oil has a fire point above a temperature of about 350 degree C, which is more than two times as high as compared to mineral oil.
Green or environmentally friendly transformer oil, on the other hand tend to be less flammable and are also known to aid in the reduction of fire spreading.In order to further maximise operational management in addition to preventing faults and damages, an advanced on-line monitoring systems could also be added to these transformers.
In arrange to meet the current and future energy challenges, there’s require for an energy efficient, market effective, grid reliable and environment friendly technology.The reply to these concerns came forward in Green Transformer concept that contains modern advances and materials in regard of fixing, cooling and protection, exchanging (tap changer) as well as control and predictive observing connected to Smart Grid technologies.The transformer offers to be eco-friendly, by limiting the carbon footprints for its shoppers. For occurrence, the oil utilized in such transformers is Ester oil produced from vegetables rather than the ordinary mineral oil; Easter oil has been rumored for their eco-friendly properties additionally for a high flash point of up to 350 degree C.
- Phase is 3Ø
- Frequency if 60Hz,50Hz
- Primary Voltage is 22.9 kV
- Secondary Voltage is 6.6/3.3 kV
- Tap Voltage 23.9-R22.9-21.9-20.9-19.9kV
- Vector Dd0, Dyn11, etc.
- Range:2500 kVA to 100,000 kVA, up to 220 kV Class
- standard:
- Distribution and power transformers: IS: 2026, BS: 171 & IEC: 76
- Converter transformers: IS: 4540, IEC: 146 & IEEE: 444
- Furnace transformers: IS: 2026
- System earthing transformers: IS: 3150 & BS: 4944
- Off-circuit tap changer to provide +5% to -5%, +7.5% to -7.5%, +10% to -10% taps
- On-load tap changer for offering +5% to -15% taps in steps of 1.25% / +5% to -15% in steps of 2.5%
- Frequency of 50 Hz in voltages of 11 KV, 22 KV, and 33 KV
- Continuous duty
- Standard fittings according to IS: 2026/IEC: 76
- HV Side cable box/Bare Brushings
- LV Side cable box/bus duct
- Environment Friendly Transformer manufacturer in india: Rwanda, Nepal, Malaw, Kenya, Bangladesh, Malaysia Tanzania, Nigeria, Africa, Uganda, India,
Find Great Deals On Eco-Friendly Transformers, Check Safe And Environmentally Friendly Large Power Transformers price
Ester liquids have been utilized in transformers for separator and cooling purposes for over 20 years. These liquids incredibly decrease natural affect and essentially moderate spillage and fire dangers. Recent experience underlines the benefits of utilizing ester liquids rather than conventional mineral oils.
IEEE C57.154-2012 |
IEC60076-14 |
||
Mineral oil |
Ester fluid |
Mineral oil† |
Ester fluid |
Maximum continuous temperature rise limits for transformers with high-temperature insulation systems |
|
|
|
Minimum required high-temperature solid insulation thermal class 120 |
140 |
120 |
140 |
Top liquid temperature rise, (°C) 65 |
90 |
60 |
90 |
Average winding temperature rise, (°C) 65 |
85 |
75 |
95 |
Hottest spot temperature rise, (°C) 80 |
100 |
90 |
110 |
Suggested maximum overload limits for transformers with high-temperature insulation systems |
|
|
|
Maximum top liquid temperature with normal life expectancy (°C) 105 |
130 |
105 |
130 |
Maximum top liquid temperature with loading above nameplate rating (°C) 110 |
140 |
115 |
140 |
Maximum solid insulation hottest spot temperature with normal life expectancy (°C) 120 |
140 |
115 |
140 |
Maximum solid insulation hottest spot temperature with planned loading beyond nameplate rating (°C) 130 |
150 |
130 |
150 |
Maximum solid insulation hottest spot temperature with long-term emergency loading (°C) 140 |
160 |
140 |
160 |
For Final Environment Friendly Transformer price india Please Mail Us on info@rajasthanpower.in
A Green Power Transformer is a sustainable, eco-efficient product with one or more of the following functionalities:
- Optimised low loss levels
- Properly sealed Hermetical tank design, with patented expandable radiator and vacuum switch equipped OLTC.
- Filled with ester oil instead of mineral oil
- On-line MS3000 monitoring system
- Innovative technologies to decrease transmission of acoustic energy along with optimized design of active components
ain Technical Parameters for 11/10.5/10/6.3/6KV level ,S11 series distribution transformer | ||||||
Rated Power (kva) |
High Voltage (kv) |
H.V.Tap range |
Low Voltage (kv) |
Connection symbol |
No-load loss(W) | On-load loss(W) |
30 |
6
6.3
10
10.5
11
|
±5
±2*2.5 |
0.4
|
Yyn0 | 0.10 | 0.60/0.63 |
50 |
Yyn0
Dyn11
Yzn1 |
0.13 | 0.87/0.91 | |||
63 | 0.15 | 1.04/1.00 | ||||
80 | 0.18 | 1.25/1.31 | ||||
100 | 0.20 | 1.50/1.58 | ||||
125 | 0.24 | 1.80/1.89 | ||||
160 | 0.27 | 2.20/2.31 | ||||
200 | 0.33 | 2.60/2.73 | ||||
250 | 0.40 | 3.05/3.2 | ||||
315 | 0.48 | 3.65/3.83 | ||||
400 | 0.57 | 4.30/4.52 | ||||
500 | 0.68 | 4.15/5.41 | ||||
630 |
Yyn0
Dyn11 |
0.81 | 6.20 | |||
800 | 0.98 | 7.50 | ||||
1000 | 1.16 | 10.30 | ||||
1250 | 1.37 | 12.00 | ||||
1600 | 1.65 | 14.50 | ||||
2000 | 1.96 | 19.8 |
Below are the tests conducted before delivery. Other tests required by clients can also be done accordingly.
- Insulation resistance
- Resistance of all windings
- Check voltage ratio and vector group
- No-load test at rated frequency and rated voltage
- Impedance test
- Withstand voltage testing
- Induced over-voltage withstand testing
- Partial discharge measurement
- Oil leakage test
- Noise reduction
- Increased safety and reliability
- High eco-efficiency
- restricted pollution risks
- lowered maintenance
- reduced ageing
- increased fire safety
- Overloadability – flexibility in load handling or minimizing footprint for mobility