5 mva power transformer manufacturers in india

An Authorized 5000 kva transformer, 5 mva 33/11kv transformer suppliers in africa, view 5 mva power transformer price in india

Transformers such as the 5 mva transformer dimensions are  considered to be one of the primary components for both the transmission as well as distribution of electrical energy. Click here for the cost of cost of 5 mva transformer in india.

5 mva power transformer manufacturers in india

 

 

5 mva transformer manufacturers in india
5 mva transformer manufacturers in india
5000 kva transformer
5000 kva transformer
5 mva 33/11kv transformer
5 mva 33/11kv transformer

 

Looking For 5 mva inverter duty transformer Exporter in india, view 5000 kva transformer price and 5 mva transformer current rating

The design of the 5 mva transformer oil capacity results mainly from the range of application, the construction, the rated power as well as the voltage level. The scope of 5 mva transformer parts types starts with generator transformers and ends with distribution type 5 mva transformer. A 5 mva power transformer which are directly connected to the generator of the power station can be referred to as a generator  5 mva 33/11kv transformer.

The power range of a 5 mva transformer current rating goes up to far above 1000 MVA. And the 5 mva transformer current capacity voltage range extends to approx. 1500 kV. Click here for the 5000 kva transformer price. Distribution 5000 kva transformer usually is produced within the range from 50 to 2500 kVA and max. 36 kV. In the last step, the 5 mva transformer full load current distributes the electrical energy to the consumers.

This is done by feeding the 5 mva inverter duty transformer from the high voltage network into a low voltage distribution network. The 5 mva transformer load capacity has been designed either as liquid- filled or as dry type transformers. Transformers with a rated power of up to 2.5 MVA including a voltage up to 36 kV can be referred to as distribution 5 mva transformer weight; on the other hand all transformers of higher ratings will be classified as power transformers.

We are one of the leading 5 mva transformer manufacturers in India. Because we offer competitive pricing all over the world, especially 5 mva power transformer price in India our client base consists of buyers in all sectors. These buyers often purchase or order different 5 mva transformer specification. Click on the link to obtain the technical specification of 5 mva transformer. We are also certified to perform 5 mva transformer testing.


what is 5 mva power transformer

MVA stands for Mega Volt Amp or Volts X Amp /1000,000. In case your add up to load necessity is 1000 volts and 5000 amps (1000 x 5000 = 5000,000 VA) it can be communicated as 5MVA. Usually called “apparent power” since it takes into thought both the resistive load and the reactive load. We generally indicate load by MVA, KVA or VA as any specific appliance of power framework generally absorbs active power as well as reactive power. ( Eg: transformers).

Partition the number of kVA by 1,000 to convert to MVA. For illustration, in case you have got 438 kVA, isolate 438 by 1,000 to induce 0.438 MVA.Multiply the number of kVA by 0.001 to change over to MVA.

5 MVA = 5000 KVA

 

technical specification of 5 mva transformer

Rating 5 MVA, 3PH, 415/6.6/11KV
Frequency 50 HZ
LT Nominal Voltage 415V, AC
LT Breaker 8000A, 3P, 415V MDO(4000AX2)
HT Nominal Voltage 6.6/11KV, AC
CT Ratio 100/5A
PT Ratio 11/110V
Capacity of Oil 250 LTR
Type of Oil TC OIL
Vector Group Y-Y
Empty Weight  
Full Weight  
Provisions Can For Step Up and Step Down Application for Step Down Application Load Should be Balanced on 3PH
5 mva transformer manufacturers in india export to Nigeria, Rwanda, Kenya, Bangladesh, Nepal, Africa, Tanzania, India, Malaysia Uganda, Malawi
Other Ratings 10, 16, 25, 50, 63, 100, 160, 200, 315, 500, 630, 750 kVA
all above transformer are 11kV , 22kV, 33kV line
Efficiency 3, 4, 5 Star or Level II, Level III

 

5000 kva transformer price

 For Final 5 mva transformer price in india Please Mail Us on info@rajasthanpower.in

 

5 mva transformer manufacturers in india

5 mva inverter duty transformer
5 mva inverter duty transformer
5 mva 33/11kv transformer
5 mva 33/11kv transformer
5000 kva transformer
5000 kva transformer
5 mva transformer
5 mva transformer

 

Find Great Deals On 5 mva transformer, Check 5 mva transformer testing, weight and full load current

 

5 mva transformer current rating

kVA stands for Kilovolt-Ampere and is the rating regularly utilized to rate a transformer. The size of a transformer is decided by the kVA of the load. In numerous circumstances the power required by the load is proportionate to the rating of the transformer communicated in either VA or kVA. For case a 1KW (1000 Watts) load would require a 1kVA transformer @ unity power factor.

KVA calculation
For three phase KVA= (V*I*1.732)/1000
For single phase KVA= (V*I)/1000

MVA calculation-
For three phase MVA= (V*I*1.732)/100,000
For single phase MVA= (V*I)/1000,000

 

Get All Type Test Report Here

5 MVA Lightning Impulse Test Report 5 MVA Short circuit Test Report 5 MVA Temperature Rise Test Report
3.15 MVA Lightning Impulse Test Report 3.15 MVA Short Circuit Test Report 3.15 MVA Temperature Rise Test Report
2000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report 1000 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Test Report 500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Paint Adhesion Test Report 500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
500 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report 315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 315 KVA, EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Coating Thickness Test Report 315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report
315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Sound Power Test Report 315 KVA, EEL-2, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report 160 KVA, Lightning Impulse Test Report
160 KVA, Short Circuit Test Report 160 KVA, Temperature Rise Test Report 100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Lightning Impulse Test Report
100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 100 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Lightning Impulse Test Report 100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Short Circuit Test Report 100 KVA, Amorphous Core , EEL-3, 11_0.433 kV, Copper Wound Distribution Transformer Temperature Rise Test Report
100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Short Circuit Test Report 100 KVA, CRGO, EEL-3, 11_0.433 kV, Aluminium Wound Distribution Transformer Sound Power Test Report 100 KVA Aluminium Wound Distribution Transformer Temperature Rise Test Report
63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 63 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 25 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report 16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Sound Power Test Report
16 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report 10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Lightning Impulse Test Report 10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Short Circuit Test Report
10 KVA, CRGO Core , EEL-2, 11_0.433 kV, Aluminum Wound Distribution Transformer Temperature Rise Test Report Single Phase 25 KVA ALuminium wound Distribution Transformer EEL-2 Single Phase 16 KVA ALuminium wound Distribution Transformer EEL-2
Single Phase 10 KVA ALuminium wound Distribution Transformer EEL-2 Single Phase 5 KVA Aluminium wound Distribution Transformer EEL-2 Single Phase 5 KVA Copper wound Distribution Transformer EEL-2

 

5 mva transformer dimensions

Main Technical Parameters for 35KV level ,S11 series distribution transformer
Rated
Power
(kva)
High 
Voltage
(kv)
H.V.Tap
range
Low 
Voltage
(kv)
Connection
symbol
No-load loss(W)  On-load loss(W)
2000 kva    35

 

   ±3*2.5

   6.3

 

   10.5

     Ynd11      2.31      19.24
2500 kva      2.72      20.65
3150 kva

   35    

   

 

 

   38.5

     3.24      24.71
4000 kva       3.88      29.12
5000 kva       4.64      34.2
6300 kva       5.64      36.8
8000 kva

    6.3

 

    6.6

   

   10.5

  

     11

    Ynd11       7.88      40.62
10000 kva       9.28      48.05
12500 kva       10.95      57.81
16000 kva       13.16      70.32
20000 kva      15.57       82.8
25000 kva       18.07

 

5 mva transformer weight

5 mva transformer weight

 

5 mva transformer testing

Below are the tests conducted by Rajasthan Powergen Transformer P. Ltd. before delivery. Other tests required by clients can also be done accordingly.

  •  Insulation resistance
  •  Resistance of all windings
  •  Check voltage ratio and vector group
  • No-load test at rated frequency and rated voltage
  • Impedance test
  • Withstand voltage testing
  • Induced over-voltage withstand testing
  • Partial discharge measurement
  • Oil leakage test

 

5 MVA transformer impedance

The impedance of a transformer is the entire restriction offered to substituting current. This may be calculated for each winding.However, a rather basic test gives a practical strategy of measuring the comparable impedance of a transformer without isolating the impedance of the windings.

Calculation of Percentage Impedance

In arrange to decide proportionate impedance, one winding of the transformer is short-circuited. And a fair sufficient voltage is connected to the other winding to make full load current to stream within the short-circuited winding.This voltage is known as the impedance voltage.

Calculation of Percentage Impedance

Impedance Data for Single-Phase Transformers

kVA

Suggested X/R Ratio
for

Normal Range of Percent
Impedance (%Z)*

Impedance Multipliers** For Line-to-Neutral
Faults

Calculation

 

for %X

for %R

25.0 kva

1.1

1.2–6.0

0.6

0.75

37.5 kva

1.4

1.2–6.5

0.6

0.75

50.0 kva

1.6

1.2–6.4

0.6

0.75

75.0 kva

1.8

1.2–6.6

0.6

0.75

100.0 kva

2.0

1.3–5.7

0.6

0.75

 

Impedance Voltage

5 MVA

7.15%

 

types of industrial transformer available

 

5 mva transformer oil capacity

Transformer oil (moreover known as insulating oil) may be a uncommon type of oil which has fabulous electrical protection properties and is steady at high temperatures. Transformer oil is utilized in oil-filled electrical power transformers to insulate, stop arcing and corona release, and to disseminate the heat of the transformer (i.e. act as a coolant).

The oil capacity of 5MVA(5000kVA) transformer is 3030 ltr.

5 mva transformer oil capacity

 

5 mva transformer load capacity

Sl. No. Capacity and voltage ratting of Power-Transformer
1 315 MVA 400/220 KV Single ph auto transformer
2 200 MVA 220/132/33 KV Auto Transformer
3 160 MVA 220/132/33 KV Auto Transformer
4 50 MVA 132/33 KV Power-Transformer
5 31.5 MVA 132/33 KV Power-Transformer
6 20 MVA 132/33 KV Power-Transformer
7 7.5 MVA 66/33 KV Power-Transformer
8 5 MVA 66/33 KV Power-Transformer
9 5 MVA 33/11 KV Power-Transformer
10 6.3 MVA 33/11 KV Power-Transformer
11 10 MVA 33/11 KV Power-Transformer

 

5 mva transformer full load current

How to use the full load chart to find kVA

A) Determine the secondary voltage of your transformer.
B) Sum up the total amperes required by the load.
C) From the full load current table below, select a transformer under the corresponding secondary voltage, with a standard kVA capacity and amperage equal to or higher than the sum required by the load.

 

Full Load Current Table (1 Phase Transformer)

kVA Current in Amperes
120V 240V 416V 480V 600V 2400V 4160V
0.25 kva 2.08 1.04 0.6 0.52 0.41
0.5 kva 4.16 2.08 1.2 1.04 0.83
0.75 kva 6.25 3.13 1.8 1.56 1.25
1 kva 8.33 4.17 2.4 2.08 1.67
1.5 kva 12.5 6.25 3.6 3.13 2.5
2 kva 16.7 8.33 4.81 4.17 3.33
3 kva 25 12.5 7.21 6.25 5 1.25 0.72
5 kva 41.6 20.8 12 10.4 8.33 2.08 1.2
7.5 kva 62.5 31.2 18 15.6 12.5 3.12 1.8
10 kva 83.3 41.6 24 20.8 16.6 4.16 2.4
15 kva 125 62.5 36 31.2 25 6.25 3.6
25 kva 208 104 60 52 41.6 10.4 6
37.5 kva 312 156 90.1 78.1 62.5 15.6 9.01
50 kva 416 208 120 104 83.3 20.8 12
75 kva 625 312 180 156 125 31.2 18
100 kva 833 416 240 208 166 41.6 24
150 kva 1250 625 360 312 250 62.5 36
167 kva 1391 695 401 347 278 69.5 40.1
250 kva 2083 1041 600 520 416 104 60
333 kva 2775 1387 800 693 555 138 80

 

Single Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

 

Horsepower Full Load Current (Amps) Minimum Transformer KVA
110-120V 208V 220-240V*
0.5 9.8 5.4 4.9 1.5 kva
0.75 13.8 7.6 6.9 2 kva
1 16 8.8 8 3 kva
1.5 20 11 10 3 kva
2 24 13.2 12 5 kva
3 34 18.7 17 5 kva
5 56 30.8 28 7.5 kva
7.5 80 44 40 15 kva
10 100 55 50 15 kva
15 135 74.8 68 25 kva
20 88 25 kva
25 110 37.5 kva
30 136 37.5 kva
40 176 50 kva
50 216 75 kva

kVA ratings include 10% overcapacity for frequent motor starts.

*For 200 volt motors, increase 220-240V ratings by 15%.

 

Full Load Current Table – 3 Phase Transformer?

kVA Current in Amperes
208V 240V 380V 416V 480V 600V 2400V 4160V
2 KVA 5.55 4.81 3.03 2.77 2.4 1.92 0.48 0.27
3 KVA 8.32 7.21 4.55 4.16 3.6 2.88 0.72 0.41
6 KVA 16.6 14.4 9.11 8.32 7.21 5.77 1.44 0.83
9 KVA 24.9 21.6 13.6 12.4 10.8 8.66 2.16 1.24
15 KVA 41.6 36 22.7 20.8 18 14.4 3.6 2.08
30 KVA 83.2 72.1 45.5 41.6 36 28.8 7.21 4.16
45 KVA 124 108 68.3 62.4 54.1 43.3 10.8 6.24
75 KVA 208 180 113 104 90.2 72.1 18 10.4
112.5 KVA 312 270 170 156 135 108 27 15.6
150 KVA 416 360 227 208 180 144 36 20.8
225 KVA 624 541 341 312 270 216 54.1 31.2
300 KVA 832 721 455 416 360 288 72.1 41.6
450 KVA 1249 1082 683 624 541 433 108 62.4
500 KVA 1387 1202 759 693 601 481 120 69.3
600 KVA 1665 1443 911 832 721 577 144 83.2
750 KVA 2081 1804 1139 1040 902 721 180 104

 

Three Phase AC Motor Full Load Running Currents in Amperes and Recommended Transformer Ratings

 

Horsepower Full Load Current (Amps) Minimum Transformer kVA
110-120V 208V 220-240V* 440-480V 550-600V
0.5 4 2.2 2 1 0.8 3 KVA
0.75 5.6 3.1 2.8 1.4 1.1 3 KVA
1 7.2 4 3.6 1.8 1.4 3 KVA
1.5 10.4 5.7 5.2 2.6 2.1 3 KVA
2 13.6 7.5 6.8 3.4 2.7 6 KVA
3 19.2 10.7 9.6 4.8 3.9 6 KVA
5 30.4 16.7 15.2 7.6 6.1 9 KVA
7.5 44 24 22 11 9 15 KVA
10 56 31 28 14 11 15 KVA
15 84 46 42 21 17 30 KVA
20 108 59 54 27 22 30 KVA
25 136 75 68 34 27 45 KVA
30 160 88 80 40 32 45 KVA
40 208 114 104 52 41 75 KVA
50 260 143 130 65 52 75 KVA
60 170 154 77 62 75 KVA
75 211 192 96 77 112.5 KVA
100 273 248 124 99 150 KVA

kVA ratings include 10% overcapacity for frequent motor starts.

* For 200 volt motors, increase 220-240V ratings by 15%.

 

5 mva transformer parts

5 mva transformer partsThese are the basic components of a 5 mva transformer.

  1. Insulating materials
  2. Windings
  3. Laminated core
  4. Tap changer
  5. Transformer oil
  6. Cooling tubes
  7. Explosion vent
  8. Breather
  9. Oil Conservator
  10. Buchholz Relay

 

 

 


5 mva transformer for sale

  • 5 mva power transformer
  • 5 mva transformer
  • 5000 kva transformer
  • 5 mva transformer
  • 5 mva 33/11kv transformer
  • 5 mva inverter duty transformer

 

Special Price Offer For 5 mva 33/11kv transformer, see 5 mva transformer oil capacity and cost of 5 mva transformer in india
Manufacturer Of 5 mva power transformer, view 5 mva transformer current capacity, current rating and dimensions