5 star rating transformer manufacturers
Prestige Quality star rated transformers suppliers in africa, view 5 star rated transformer price
Star Rated Transformers such as the 5 star rated transformer is considered to be an energy efficient transformer. The 5 star rating transformer manufacturers started production of these products as a part of the Green Campaign. These are bee star rated transformers which carry standard specifications as per Bureau of Energy Efficiency, or shortly referred to as BEE.
5 star rating transformer manufacturers
star rated transformers
5 Star Transformer
World-Class 5 Star Transformer Exporter in india, view 5 star rated distribution transformer price
The Bureau of Energy Efficiency, otherwise known as the BEE is an agency of the Government of India. The Bureau of Energy Efficiency was created in March 2002 under the provisions of India’s 2001 Energy Conservation Act under the Ministry of Power. The agency’s main function is to develop programs such as star rated transformers that will increase the conservation as well as efficient use of energy in India.
5 star rated distribution transformer is generally rated from star one to star five. These ratings are based on their performance, although in the case of these transformers star one is the segment where the loss is considered to be the highest and lowest loss segment would be defined as 5 star transformer specification.
The maximum losses equivalent to BEE 5 star transformer losses rating must not exceed the values at rated voltage as well as rated frequency which are permitted at 75 Deg. C. For instance, the indicated Max. Losses @ 50% load for a 5 star transformer socket would be 435 Watts and the Voltage ratio for the 5 Star Transformer would be 11000/ 433 V.
We are one of the leading suppliers, dealers and manufacturers of star rating transformer India.
We’ve accomplished 5-Star BEE names for these evaluations, with tests of each rating being Type Tested in a NABL Lab before accomplishing the Star Name. These transformers are majorly obtained by SEBs/DISCOMs & by Turnkey Companies executing projects on behalf of SEBs/DISCOMs.The notable highlight of the 5 star rating transformer is the truth that only add up to losses are indicated, both at 50% loading and at 100% loading, so that the manufacturer may utilize his plan skill and ideal materials to attain the given losses. Individual loss figures (no load loss and load loss) are not indicated.
The referred Indian Standard are IS1180 (part 1) Outdoor type three-phase distribution transformers upto and counting 200kVa, 11kV – detail, IS2026 (part 2). The standard evaluations secured beneath this pilot energy naming scheme is 16, 25, 63, 100, 160 and 200kVa and non standard evaluations from 16 to 200kVa.Star Rated Transformers are energy effective transformers begun as a “Green Campaign”. These are transformers that carry standard details as per Bureau of Energy Efficiency (BEE).
We are among the reputed organizations, highly engaged in providing an optimum quality range of 250KVA 5 Star Distribution Transformer.
Range | 160 kVA to 2500 kVA, up to 33 kV Class |
Ratings | Three Phase CRGO – Upto 200 kVA |
Applicable Standards | IS, REC, CEA, CBIP, IEC, Etc. |
Standards |
|
Cooling | ONAN |
Insulating Fluid | Mineral Oil to specification |
Frequency | 50 Hz |
Primary voltage | Upto 11000 V |
Secondary Voltage | 433 V |
Winding material | Copper/Aluminium |
4 star transformer manufacturers in india export to | India, Nepal, Africa, Nigeria, Uganda, Malaw, Rwanda, Tanzania, Malaysia, Kenya, Bangladesh, |
Temperature Rise | 35 C / 40 C |
For Final 5 star rated distribution transformer price india Please Mail Us on info@rajasthanpower.in
Request A Quote Today For star rating transformer india, Check 5 star transformer specification
Case |
Basis of losses (Total at 50% Load Condition) |
Base case Star 1 |
Current purchasing practice (IS 1180 (part 1)Max Losses) |
Star 2 |
Some utility purchase specs like AP, NDPL |
Star 3 |
Losses from TOC design (Moderate) |
Star 4 |
Losses from lowest TOC design |
Star 5 |
High efficiency design |
Star Rating plan
The total losses at 50% and 100% loading shall not exceed the values given below:
Rating |
1 star |
2 star |
3 star |
4 star |
5 star |
|||||
kVA |
Max Losses at 50% (Watts) |
Max Losses at 100% |
Max Losses at 50% (Watts) |
Max Losses at 100% |
Max Losses at 50% (Watts) |
Max Losses at 100% |
Max Losses at 50% (Watts) |
Max Losses at 100% |
Max Losses at 50% (Watts) |
Max Losses at 100% |
16 |
200 |
555 |
165 |
520 |
150 |
480 |
135 |
440 |
120 |
400 |
25 |
290 |
785 |
235 |
740 |
210 |
695 |
190 |
635 |
175 |
595 |
63 |
490 |
1415 |
430 |
1335 |
380 |
1250 |
340 |
1140 |
300 |
1050 |
100 |
700 |
2020 |
610 |
1910 |
520 |
1800 |
475 |
1650 |
435 |
1500 |
160 |
1000 |
2800 |
880 |
2550 |
770 |
2200 |
670 |
1950 |
570 |
1700 |
200 |
1130 |
3300 |
1010 |
3000 |
890 |
2700 |
780 |
2300 |
670 |
2100 |
For non standard rated transformer from 16 kVA upto 200 kVA which is not listed above
the total losses at 50% and 100% loading for a given non standard rated transformer is going to be determined by the following equations :
Where;
- K = kVA rating of the transformer L = losses
- ML = Maximum Losses for a given star rating.
- X0 = kVA rating of the Non Standard Rating transformer
- X1 = kVA rating of the Standard rated transformer below X0 X2 = kVA rating of the Standard rated transformer above X0
- L2 = Maximum Losses for a given star rating of standard rating transformer above X0 @ a particular loading.
- L1 = Maximum Losses for a given star rating of standard rating transformer below X0 @ a particular loading.
- MLX1 = Maximum Losses of X1 @ a particular loading for a given star rating.
- Trouble free performance
- Modern manufacturing techniques ensuring quality of product
- Robust build designed to withstand electric impulses, thermal and dynamic stress
- Designs through Computer Aided Design (CAD) Software System
- Available in Stack core
- Customized design and specification demands
- Low Losses making it environment-friendly
- Lowers the equipment running costs thus making the transformer Cost-effective in the long run
- Reduces energy consumption
- Commercial
- Industrial
|
|
Standard Fittings | Optional Fittings |
|
|
- Minimum Order Quantity: 1 Piece.
- Delivery Terms: F.O.R. destination.
- Delivery Time: As per customer requirement.
- Packaging Details: As per customer requirement.